AI summary · arXiv: 1807.05408v3 · eess.SP

Non-contact Vital Signs Monitoring through Visible Light Sensing

Hisham Abuella, Sabit Ekin
Original paper · DOI 10.1109/jsen.2019.2960194 Submitted to arXiv on 14 Jul. 2018 Published in IEEE Sensors Journal (01 Apr. 2020) License: NONEXCLUSIVE-DISTRIB 1.0

How to read this summary? Illustrated guide

The essentials

  • The paper presents a non-contact vital signs monitoring system using visible light sensing (VLS) technology
  • The system wirelessly senses respiration and heartbeat using only reflected incoherent light signals from a human subject
  • It is an attractive, low-cost, and safe method for vital signs monitoring
  • The VLS-based system uses a simple visible light source, photodetector, and data acquisition/processing unit
  • Signal processing algorithms turn slight variations in reflected light power into accurate measurements of respiration and heart rate
  • More than 94% accuracy was observed in test results compared to contact-based vitals monitoring devices
  • This technology has potential to address numerous conditions and situations where vital signs are critical indicators such as sleep apnea and human computer interaction applications.
  • The authors of the paper are Hisham Abuella and Sabit Ekin.
  • VLS technology can be used effectively for non-contact vital sign monitoring with high accuracy levels comparable to contact-based devices while offering advantages such as safety and cost-effectiveness over other existing technologies.

Key points written by AI: they may contain errors, check them against the paper.

AI-generated keywords: VLS Non-Contact Vitals Monitoring Accuracy Cost-Effectiveness

Read further

  • Comprehensive Summary
  • Layman's Summary
  • Blog article
  • Original abstract
This paper presents a groundbreaking non-contact vital signs monitoring system that utilizes visible light sensing (VLS) technology. The system wirelessly senses respiration and heartbeat using only reflected incoherent light signals from a human subject, making it an attractive, low-cost, and safe method for vital signs monitoring. The VLS-based system is implemented by using a simple visible light source, photodetector, and data acquisition/processing unit. Developed signal processing algorithms turn slight variations in reflected light power into accurate measurements of respiration and heart rate. To assess the accuracy of the method, the results were compared with reliable measurements using a contact-based monitoring device (ground truth). More than 94% accuracy was observed in test results including both breathing and heartbeat rates in different scenarios as compared to state-of-the-art baseline methods such as contact-based vitals monitoring devices. This study represents a substantive departure from traditional non-contact vitals monitoring methods such as radio-frequency-based radars and imaging-based cameras. It has significant implications for the healthcare community since vital signs monitoring is ubiquitous in medicine. This technology has potential to address numerous conditions and situations where vital signs are critical indicators such as sleep apnea and human computer interaction applications. The authors of this paper are Hisham Abuella and Sabit Ekin whose work demonstrates that VLS based vitals monitoring innovation is indeed viable, powerful, attractive, low cost and safe. This research has made big contributions to this area by providing an alternative to traditional non contact vitals monitoring methods which will impact patients in their homes, doctor's offices large medical institutions and industries alike. Overall this study provides evidence that VLS technology can be used effectively for non contact vital sign monitoring with high accuracy levels comparable to contact based devices while offering advantages such as safety and cost effectiveness over other existing technologies.

Was this synthesis useful?

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

Figures and plots

Ask about a figure by number or use its question button to request visual analysis. Up to two figures and four image panels per question. Values read from plots are approximate; check the original data.

AI assistant instructions?

Tools for this paper

Explain it differently 1 free rewrite left today
Save to a collection Group papers in collections to compare them, chat with them and export them. Continue with Google Create a free account Log in

Advanced tools Premium

For researchers who follow a field closely: citation alerts, journal-club slides, version comparison and Zotero export. Discover Premium

Zotero Zotero guide
Citation alerts 47 papers already cite it: be emailed each new one. Citation alerts guide
Who works on it?

Among the 31 papers around this one, the name that comes back most: M. Villarroel (3 papers)

5 more people sign several of them. The full map adds their institutions and approaches, from the papers of the last years.

Continue with Google Create a free account: your first map is free
Weekly letter The latest letter of its field, "Computing beyond AI this week" of 23 November 2026: Computing beyond AI this week: The hidden limits of shared machines · Receive one by email for free

Papers around this one

See them on a map

Ranked by how close their title and abstract are to this paper’s. Select some to read them together.

Closest papers

  1. Very close Cited by this paper
    A New Paradigm for Non-contact Vitals Monitoring using Visible Light Sensing
    Hisham Abuella, S. Ekin · 2019 · Annual IEEE Communications Society Conference on Sensor, Mesh and Ad Hoc Communications and Networks · cited 4 times · Not summarized yet
    Abstract

    Typical techniques for tracking vital signs require body contact and most of these techniques are intrusive in nature. Body-contact methods might irritate the patient’s skin and he/she might feel uncomfortable while sensors are touching his/her body. In this study, we present a new wireless (non-contact) method for monitoring human vital signs (breathing and heartbeat). We have demonstrated for the first time1 that vitals signs can be measured wirelessly through visible light signal reflected from a human subject, also referred to as visible light sensing (VLS). In this method, the breathing and heartbeat rates are measured without any body-contact device, using only a simple photodetector a…

  2. Very close Cited by this paper
    Non-contact video-based vital sign monitoring using ambient light and auto-regressive models
    L. Tarassenko, M. Villarroel, Alessandro Guazzi et al. · 2014 · Physiological Measurement · cited 436 times · Not summarized yet
    Abstract

    Remote sensing of the reflectance photoplethysmogram using a video camera typically positioned 1 m away from the patient’s face is a promising method for monitoring the vital signs of patients without attaching any electrodes or sensors to them. Most of the papers in the literature on non-contact vital sign monitoring report results on human volunteers in controlled environments. We have been able to obtain estimates of heart rate and respiratory rate and preliminary results on changes in oxygen saturation from double-monitored patients undergoing haemodialysis in the Oxford Kidney Unit. To achieve this, we have devised a novel method of cancelling out aliased frequency components caused by …

  3. Very close
    Photoplethysmography and vital sign measurement using 3D-multispectral multimodal imaging
    Wang Liao, Chen Zhang, M. Rosenberger et al. · 2026 · PHOTOMET EDUMET · Not summarized yet
    Abstract

    Contactless vital-sign monitoring can improve comfort and hygiene in long-term, sleep, home, and clinical monitoring, but robust estimation of heart rate (HR), respiratory rate (RR), and oxygen saturation (SpO2) remains a coupled sensing and algorithmic problem. This paper summarizes our research line on remote photoplethysmography and vital sign measurement using 3D-multispectral multimodal imaging. We first review the CoViTal system, which integrates RGB, NIR, thermal, and 3D imaging for registered multimodal acquisition and 3Dsupported ROI tracking. We then describe a miniaturized multispectral multi-aperture camera (MAC) as a compact extension toward portable and home-oriented monitoring…

  4. Very close Cites this paper
    The Fundamental Limits of Light-Wave Sensing for Non-Contact Respiration Monitoring
    Brenden Martin, Md Zobaer Islam, Carly Gotcher et al. · 2023 · arXiv.org · preprint, not peer reviewed · Not summarized yet
    Abstract

    An experimental testbed has been constructed to assess the capabilities of Light-Wave Sensing, a promising new vitals monitoring approach. A Light-Wave Sensing apparatus utilizes infrared radiation to contactlessly monitor the subtle respiratory motions of a subject from meters away. A respiration-simulating robot was programmed to produce controllable, humanlike chest displacement patterns for accuracy analysis. Estimation of respiration rate within tenths of a breath per minute has been demonstrated with the testbed, establishing the tenability of the method for use in commercial non-contact respiration monitoring equipment, and setting practical expectations on the usable range of this se…

  5. Very close Cited by this paper
    Continuous non-contact vital sign monitoring in neonatal intensive care unit
    M. Villarroel, Alessandro Guazzi, João Jorge et al. · 2014 · Healthcare technology letters · cited 195 times · Not summarized yet
    Abstract

    Current technologies to allow continuous monitoring of vital signs in pre-term infants in the hospital require adhesive electrodes or sensors to be in direct contact with the patient. These can cause stress, pain, and also damage the fragile skin of the infants. It has been established previously that the colour and volume changes in superficial blood vessels during the cardiac cycle can be measured using a digital video camera and ambient light, making it possible to obtain estimates of heart rate or breathing rate. Most of the papers in the literature on non-contact vital sign monitoring report results on adult healthy human volunteers in controlled environments for short periods of time. …

  6. Very close
    Touch-Free Vital Signs Monitoring for Burn Victims Using Radar System
    Lohith J, M. Ramesh, M. N et al. · 2026 · International Journal of Creative and Open Research in Engineering and Management · Not summarized yet
    Abstract

    Touch-free vital sign monitoring is particularly useful for burn victims and critically ill patients, for whom conventional sensor attachment can cause pain, irritation, or infection. This paper presents a contactless system for real-time monitoring of respiration rate, heartbeat activity, and body temperature using non-invasive sensing techniques integrated with an embedded processing unit. The acquired signals are processed using signal conditioning and filtering techniques to reduce noise and improve measurement reliability. The proposed system is designed to be low-cost, portable, and suitable for real-time operation in burn care units, intensive care, emergency, and remote healthcare en…

  7. Very close Cites this paper
    Fundamental limits of light-wave sensing for non-contact respiration monitoring
    Brenden Martin, Md Zobaer Islam, Carly Gotcher et al. · 2024 · Biomedical Optics Express · Not summarized yet
    Abstract

    An experimental testbed was constructed to rigorously assess the fundamental limits of light-wave sensing—an economic, non-contact vitals monitoring approach previously reported. We improve the testbed using lock-in amplification and demonstrate that a photodetector and a commonplace array of infrared LEDs are sufficient to detect respiratory motion and quantify respiration rate up to 2.5 meters away. We propose a novel scattering model, from which we derive the performance limits of the light-wave sensing system in terms of a theoretical range resolution limited by the dynamic range of the system. Using a robotic breathing phantom, we experimentally assess, for the first time, the range res…

  8. Close Cites this paper
    Millimeter-Wave Radar Assisted Multimodal Vital Sign Signal Extraction and Analysis Method
    Yansong Wu, Cai-Li Gong, Yong-Feng Wei et al. · 2025 · International Conference on Signal Processing and Machine Learning · cited 1 time · Not summarized yet
    Abstract

    Conventional contact-based vital sign monitoring methods have notable limitations in specialized clinical scenarios, such as cases of skin burns. These methods are susceptible to environmental interference and may also lead to tissue damage or patient discomfort, increasing the risk of infection and hindering wound healing. To address these challenges, we propose a novel non-contact vital sign monitoring system utilizing millimeter-wave radar technology. The proposed system employs Frequency Modulated Continuous Wave (FMCW) radar technology, integrated with Multiscale Decomposition and Orthogonal Matching Pursuit (OMP) algorithms, as well as a time-frequency domain-fused Kalman Filter approa…

Prior work it builds on

  1. Close Used in depth by this paper A method it uses
    Smart Homes that Monitor Breathing and Heart Rate
    Fadel M. Adib, Hongzi Mao, Zachary Kabelac et al. · 2015 · International Conference on Human Factors in Computing Systems · cited 934 times · Not summarized yet
    Abstract

    The evolution of ubiquitous sensing technologies has led to intelligent environments that can monitor and react to our daily activities, such as adapting our heating and cooling systems, responding to our gestures, and monitoring our elderly. In this paper, we ask whether it is possible for smart environments to monitor our vital signs remotely, without instrumenting our bodies. We introduce Vital-Radio, a wireless sensing technology that monitors breathing and heart rate without body contact. Vital-Radio exploits the fact that wireless signals are affected by motion in the environment, including chest movements due to inhaling and exhaling and skin vibrations due to heartbeats. We describe …

  2. Close* A method it uses
    Contactless Multiple Wavelength Photoplethysmographic Imaging: A First Step Toward “SpO2 Camera” Technology
    F. Wieringa, F. Mastik, A. V. D. van der Steen · 2005 · Annals of Biomedical Engineering · cited 312 times · Not summarized yet
  3. Close A method it uses
    Contact-free Measurement of Heart Rate Variability via a Microwave Sensor
    Guohua Lu, Fang Yang, Yue Tian et al. · 2009 · Italian National Conference on Sensors · cited 60 times · Not summarized yet
    Abstract

    Measures of heart rate variability (HRV) are widely used to assess autonomic nervous system (ANS) function. HRV can be recorded via electrocardiography (ECG), which is both non-invasive and widely available. However, ECG needs three electrodes touching the body of the subjects, which makes them feel nervous and uncomfortable, thus potentially affecting the recording. Contact-free detection of the heartbeat via a microwave sensor constitutes another means of determining the timing of cardiac cycles by continuous monitoring of mechanical contraction of the heart. This technique can measure the heartbeat without any electrodes touching human body and penetrate the clothes at some distances, whi…

  4. Close*
    Camera-based system for contactless monitoring of respiration
    Marek Bartula, Timo Tigges, J. Muehlsteff · 2013 · Annual International Conference of the IEEE Engineering in Medicine and Biology Society · cited 133 times · Not summarized yet
  5. Close*
    A non-contact lie detector using radar vital signs monitor (RVSM) technology
    J. Geisheimer, E. Greneker · 2001 · IEEE Aerospace and Electronic Systems Magazine · cited 42 times · Not summarized yet

Papers that cite it

  1. Close Uses this paper in depth
    Device-Free Visible Light Sensing: A Survey
    Morteza Alijani, Cedric De Cock, Wout Joseph et al. · 2026 · IEEE Communications Surveys and Tutorials · cited 28 times · Not summarized yet
    Abstract

    The latest advancements in visible light communication (VLC) technology have greatly facilitated the evolution of wireless sensing based on visible light, commonly referred to as visible light sensing (VLS) systems. Similar to other wireless sensing technologies, these systems can be categorized into two primary types: device-based (or active) and device-free (or passive), depending on whether targets, such as people or objects of interest, are equipped with an optical receiver (e.g., a photodiode or camera). By reusing the existing Light-emitting diode (LED) lighting infrastructure as transmitters in indoor environments, device-free VLS (DF-VLS) systems can help address the growing energy d…

  2. Close Uses this paper in depth
    A systematic review of non-contact medical IoT systems for physiological biomarker monitoring
    Bithi Banik, Saptanil Ghose, Ahnaf Hasnain Nahiun et al. · 2026 · Frontiers in Medical Technology · Not summarized yet
    Abstract

    Introduction Non-contact medical Internet of Things systems measure physiological biomarkers such as heart rate (HR), respiration rate (RR), temperature, oxygen saturation (SpO₂), and blood pressure (BP) without physical contact with the patient. These systems combine sensing modalities including cameras, radar, Wi-Fi, acoustic, and infrared sensors with signal processing and learning algorithms to deliver comfortable, non-invasive monitoring. Prior reviews have largely examined individual sensing modalities or signal processing techniques in isolation, leaving cross-modality system architecture and privacy-preserving design underexamined. Methods We conducted a systematic review following P…

  3. Close Uses this paper in depth
    A Feasibility Study of Remote Non-Contact Vital Signs (NCVS) Monitoring in a Clinic Using a Novel Sensor Realized by Software-Defined Radio (SDR)
    Yang Liu, C. Sweeney, J. Mayeda et al. · 2023 · Biosensors · cited 7 times · Not summarized yet
    Abstract

    The COVID-19 outbreak has caused panic around the world as it is highly infectious and has caused about 5 million deaths globally. A robust wireless non-contact vital signs (NCVS) sensor system that can continuously monitor the respiration rate (RR) and heart rate (HR) of patients clinically and remotely with high accuracy can be very attractive to healthcare workers (HCWs), as such a system can not only avoid HCWs’ close contact with people with COVID-19 to reduce the infection rate, but also be used on patients quarantined at home for telemedicine and wireless acute-care. Therefore, we developed a custom Doppler-based NCVS radar sensor system operating at 2.4 GHz using a software-defined r…

  4. Close
    Non-Invasive Data Acquisition and IoT Solution for Human Vital Signs Monitoring: Applications, Limitations and Future Prospects
    Mahmoud Salem, A. Elkaseer, I. El-Maddah et al. · 2022 · Italian National Conference on Sensors · cited 37 times · Not summarized yet
    Abstract

    The rapid development of technology has brought about a revolution in healthcare stimulating a wide range of smart and autonomous applications in homes, clinics, surgeries and hospitals. Smart healthcare opens the opportunity for a qualitative advance in the relations between healthcare providers and end-users for the provision of healthcare such as enabling doctors to diagnose remotely while optimizing the accuracy of the diagnosis and maximizing the benefits of treatment by enabling close patient monitoring. This paper presents a comprehensive review of non-invasive vital data acquisition and the Internet of Things in healthcare informatics and thus reports the challenges in healthcare inf…

  5. Close
    Survey, Analysis and Comparison of Radar Technologies for Embedded Vital Sign Monitoring
    Marco Giordano, G. Islamoglu, Viviane Potocnik et al. · 2022 · Annual International Conference of the IEEE Engineering in Medicine and Biology Society · cited 12 times · Not summarized yet
    Abstract

    Contactless vital sign monitoring systems are becoming increasing in demand for a wide range of biomedical applications. Millimetre-wave radars and embedded signal processing are the most promising technologies to enable non-contact vital signs monitoring. In this work, the challenging task of heart rate estimation from radar data has been addressed. Three different radar systems from Infineon, Texas Instruments and Acconeer, and four algorithms, FFT, Median-FFT, STFT and Median-STFT, have been analysed and compared against a reference sensor. Accuracy, as well as power figures, have been reported for all the radar systems. A dataset of 16 volunteers has been acquired, yielding a total of 40…

How are these papers found?

We compare the title and abstract of this paper with those of every paper summarized on this site, and with the papers Semantic Scholar recommends, those it cites and those citing it (for a much-cited paper, its most recent citations and, from OpenAlex, the most cited ones). Among the prior work and the follow-ups, the papers that use each other in depth, a method it uses and the much-cited follow-ups come a little higher. The levels (very close, close, related) come from the similarity of the texts, not from a judgment of quality; * marks a paper without an abstract, compared by its title. The sentence under a paper is written by an AI from the two abstracts: check it in the papers. A paper marked not relevant by three readers leaves the list.

Updated on 5 November 2026.

The illustrated guide to the papers around a paper

The previous summary was created more than a year ago and can be re-run (if necessary) by clicking on the Run button below.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.