AI summary · arXiv: 2610.34250v1 · physics.optics
Yb/Sr optical clock comparison at 2.2E-18 uncertainty over a 1350-km fiber link
The essentials
A 1,350-km fiber comparison of Wuhan Yb and Shanghai Sr clocks determined their frequency ratio with 2.18×10⁻¹⁸ total uncertainty and detected a tidal signal.
Question
Can different optical clocks in separate cities be compared over a long-distance link with uncertainty below 5×10⁻¹⁸, as required for validating clock evaluations? Can the same comparison detect time-varying gravitational potential from Earth tides?
Method
The authors linked a ytterbium lattice clock in Wuhan and a strontium lattice clock in Shanghai using a phase-stabilized 1,350-km fiber network. Across 58 days, they collected 274 effective hours in 16 jump-free segments, combined segment ratios with a random-effect model, and assessed tidal response against a template based on DE421 ephemerides and the FES2022 ocean-tide model.
Findings
-
Result
The measured Yb/Sr frequency ratio was 1.2075070393433377160, with total standard uncertainty 2.18×10⁻¹⁸.
See the passage in the paper
Combining these components in quadrature gives the total standard uncertainty $2.18\times 10^{-18}$; the reported ratio is therefore
-
Authors’ interpretation
The ratio comparison reached the uncertainty level required by the redefinition roadmap for comparisons between different transitions in different laboratories.
See the passage in the paper
To our knowledge, this is the first intercity long distance frequency-ratio measurement whose total uncertainty reaches the level required by the redefinition roadmap.
-
Result
The measured beat showed a tidal-template response amplitude of 0.87(15), differing from zero by 5.7 standard deviations and consistent with the expected response of +1.
See the passage in the paper
The within-segment correlation against a template built from the DE421 ephemerides 33 and the FES2022 ocean-tide model 34 is positive in 12 out of 16 segments, and the precision-weighted response amplitude is $0.87\,(15)$ ($1\sigma$), which differs from zero at $5.7\sigma$ and agrees with the expected response of $+1$ within the statistical uncertainty.
-
Authors’ interpretation
The comparison demonstrates that an intercity optical-clock link can measure time-varying gravitational potential at the 10⁻¹⁸ level.
See the passage in the paper
Clock comparisons over large baselines directly sense the time-variable gravitational potential, providing an independent means of testing and calibrating tide and loading models at the $10^{-18}$ level, where the limits of the current model seen here can be refined, or removed, by more comparison data from an expanding optical-clock network.
Limitations
- The reported ratio does not eliminate uncertainty in the clock systematic evaluations; the discrepancy with the NIST–JILA measurement remains unresolved.
See the passage in the paper
The remaining disagreement with the NIST–JILA determination keeps the accuracy budgets of the participating clocks open questions, which the redefinition of the second requires to be closed.
- The tide model is not equally reliable for all components: the correction degrades the record in the ocean-loading band, identifying that model component as weaker.
See the passage in the paper
In the diurnal and semi-diurnal ocean-loading band it degrades it, indicating that the ocean-loading model is the weaker part.
Why it matters
The result extends clock-ratio comparisons at the required uncertainty from local measurements to an intercity link, supporting validation of optical-clock evaluations. The authors argue that expanding such networks can also improve gravity and tide models and enable wide-area clock comparisons.
Written by AI from the paper. Passages are checked word for word against the text we analysed; the rest may contain errors.
Ask questions about this paper to our AI assistant
How to chat with this paper? Illustrated guide
You can also chat with multiple papers at once here.
Keep this conversation — a free account saves your questions and answers, your collections of papers and your alerts.
Create a free accountTools for this paper
Advanced tools Premium
For researchers who follow a field closely: citation alerts, journal-club slides, version comparison and Zotero export. Discover Premium
Papers around this one
See them on a mapRanked by how close their title and abstract are to this paper’s. Select some to read them together.
Closest papers
-
International atomic clock comparison achieving $5\times 10^{-18}$ uncertaintyA. Tofful, M. Filzinger, T. Schmidt et al. · 2026 · Atomic Physics · AI summary available
The study compares optical clocks in separate countries over a long fiber link, measuring their frequency ratio at uncertainty below 5×10⁻¹⁸.
In short
Two optical clocks compared internationally over a 2220 km fiber link agree within 4.8 × 10⁻¹⁸ fractional uncertainty and tighten constraints on Lorentz-invariance violations.
-
International optical clock comparison using the european optical fiber networkM. Pizzocaro, C. Zyskind, A. Amy-Klein et al. · 2026 · Physical Review Research · cited 8 times · Not summarized yet
The study compares seven optical clocks across European institutes over a fiber network to assess international frequency-ratio consistency.
Abstract
Optical clocks have achieved remarkable estimated fractional frequency uncertainties reaching the $10^{-18}$ level and below, enabling applications in fundamental physics, general relativity, and geodesy. However, the challenge of verifying the international consistency of optical clocks remains critical as efforts intensify toward redefining the SI second based on an optical transition or transitions. We report on a two-month international clock comparison campaign involving seven optical clocks in four national metrology institutes (INRIM, LNE-OP, NPL, and PTB) connected via the optical fiber network established in Europe. The campaign resulted in optical frequency ratios with uncertaintie…
-
Coordinated international comparisons between optical clocks connected via fiber and satellite linksThomas Lindvall, M. Pizzocaro, R. Godun et al. · 2025 · Optica · cited 36 times · Not summarized yet
The study measures frequency ratios among clocks in several countries using fiber and satellite links, addressing coordinated international comparison.
Abstract
Optical clocks provide ultra-precise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time, while others had significantly lower uncertainties than previously achieved, supporting the advance towards a redefinition of the sec…
-
Atomic Clock Frequency Ratios with Fractional Uncertainty ≤3.2×10^{-18}.A. Aeppli, Willa J. Arthur-Dworschack, K. Beloy et al. · 2026 · Physical Review Letters · cited 13 times · Not summarized yet
The study measures optical-clock frequency ratios at similarly low uncertainty using a shared ultrastable reference over a 3.6-km link.
Abstract
We report high-precision frequency ratio measurements between optical atomic clocks based on ^{27}Al^{+}, ^{171}Yb, and ^{87}Sr. With total fractional uncertainties at or below 3.2×10^{-18}, these measurements meet an important milestone criterion for redefinition of the second in the International System of Units. Discrepancies in ^{87}Sr ratios at approximately 1×10^{-16} and the Al^{+}/Yb ratio at 1.6×10^{-17} in fractional units compared to our previous measurements underscore the importance of repeated, high-precision comparisons by different laboratories. A key upgrade from our previous work is the use of a common ultrastable reference delivered to all clocks via a 3.6-km phase-stabili…
-
Frequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging timeN. Nemitz, T. Ohkubo, M. Takamoto et al. · 2016 · Nature Photonics · cited 223 times · Not summarized yet
The study measures the frequency ratio of ytterbium and strontium clocks, but uses co-located cryogenic clocks and common-mode laser-noise rejection.
Abstract
The most accurate ratio of the clock transition frequencies between Yb and Sr is measured by using a pair of cryogenic optical lattice clocks. Through common mode rejection of the clock laser noise, a uncertainty of 4.6 × 10−17 is achieved in 150 seconds. Transition frequencies of atoms and ions are among the most accurately accessible quantities in nature, playing important roles in pushing the frontiers of science by testing fundamental laws of physics, in addition to a wide range of applications such as satellite navigation systems. Atomic clocks based on optical transitions approach uncertainties of 10−18 (refs 1–3), where full frequency descriptions are far beyond the reach of the SI se…
-
Improved systematic evaluation of a strontium optical clock with uncertainty below 1×10−18Zhi-Peng Jia, Jie Li, De-Quan Kong et al. · 2025 · Metrologia · cited 19 times · Not summarized yet
The study evaluates the Sr optical clock’s systematic uncertainty, establishing clock accuracy relevant to the Wuhan–Shanghai ratio measurement.
Abstract
We report a systematic uncertainty of 9.2×10−19 for the Sr1 optical lattice clock at the University of Science and Technology of China (USTC), achieving accuracy at the level required for the roadmap of the redefinition of the SI second. A finite-element model with in situ-validated, spatially-resolved chamber emissivity reduced blackbody radiation (BBR) shift uncertainty to 6.3×10−19. Concurrently, the externally mounted lattice cavity, by providing a larger beam waist, reduced the atomic density and thereby suppressed the density shift. Enhanced lattice depth modulation consolidated lattice light shift uncertainty to 6.3×10−19 by enabling simultaneous determination of key polarizabilities …
-
Lu+ optical frequency references with accuracy verified at the 19th digitK. J. Arnold, M. Lee, Qi Zhao et al. · 2025 · Nature · cited 7 times · Not summarized yet
The study compares two lutetium-ion references to verify agreement at high accuracy, addressing clock consistency rather than intercity links.
Abstract
Optical atomic frequency references1 have far surpassed their microwave frequency predecessors, leading to an anticipated redefinition of the SI (International System of Units) second2. However, as the scientific community seeks consensus on a new standard, and several state-of-the-art optical standards now report evaluated fractional uncertainties below 10−18, verification by same-species comparisons to comparable levels remains an outstanding challenge. Here we report two 176Lu+ single-ion optical frequency references, each with evaluated fractional frequency uncertainty near 1 × 10−19, which are directly compared by correlation spectroscopy and demonstrate agreement, with a measured relat…
-
Geodesy and metrology with a transportable optical clockJ. Grotti, S. Koller, S. Vogt et al. · 2017 · Nature Physics · cited 468 times · Not summarized yet
The study uses a transportable strontium clock to measure a gravity-potential difference, applying optical clocks to geodesy.
Abstract
Optical atomic clocks, due to their unprecedented stability1–3 and uncertainty3–6, are already being used to test physical theories7,8 and herald a revision of the International System of Units9,10. However, to unlock their potential for cross-disciplinary applications such as relativistic geodesy11, a major challenge remains: their transformation from highly specialized instruments restricted to national metrology laboratories into flexible devices deployable in different locations12–14. Here, we report the first field measurement campaign with a transportable 87Sr optical lattice clock12. We use it to determine the gravity potential difference between the middle of a mountain and a locatio…
Prior work it builds on
-
Optical atomic clocks: defining the future of time and frequency metrologyTara Fortier, A. Luiten, H. Margolis · 2025 · Optica · cited 30 times · Not summarized yet
The titled article surveys optical atomic clocks and their role in future time and frequency metrology.
-
NTSC SrII optical lattice clock with uncertainty of 2×10−18Xiao-Tong Lu, Feng Guo, Yan-Yan Liu et al. · 2025 · Metrologia · cited 15 times · Not summarized yet
The study evaluates the NTSC SrII clock’s systematic uncertainty, characterizing a strontium standard relevant to clock comparisons.
Abstract
We report the systematic evaluation of the SrII optical lattice clock (OLC) at the National Time Service Center, achieving an uncertainty of 1.96×10−18. The newly established 87Sr OLC controls the black-body radiation shift by moving atoms into a temperature-stabilized chamber for clock transition detection. It mitigates the DC Stark shift by using conductive optical films on the inner windows, and reduces both the density shift and AC Stark shift by operating the clock with a relatively low lattice trap depth. Additionally, this clock accommodates changes in the angle between the lattice and gravity directions by rotating the entire setup, allowing for convenient adjustment of the tunneling…
-
Atomic clock performance enabling geodesy below the centimetre levelW. McGrew, X. Zhang, R. Fasano et al. · 2018 · Nature · cited 600 times · Not summarized yet
The study demonstrates local optical-clock measurements for geodesy, where clock frequency responds to gravity potential.
Abstract
The passage of time is tracked by counting oscillations of a frequency reference, such as Earth’s revolutions or swings of a pendulum. By referencing atomic transitions, frequency (and thus time) can be measured more precisely than any other physical quantity, with the current generation of optical atomic clocks reporting fractional performance below the 10−17 level1–5. However, the theory of relativity prescribes that the passage of time is not absolute, but is affected by an observer’s reference frame. Consequently, clock measurements exhibit sensitivity to relative velocity, acceleration and gravity potential. Here we demonstrate local optical clock measurements that surpass the current a…
-
Geodetic methods to determine the relativistic redshift at the level of 10$$^{-18}$$-18 in the context of international timescales: a review and practical resultsH. Denker, L. Timmen, C. Voigt et al. · 2018 · Journal of Geodesy · cited 111 times · Not summarized yet
The study reviews geodetic methods for determining relativistic redshift and reports practical results for international timescales.
Abstract
The frequency stability and uncertainty of the latest generation of optical atomic clocks is now approaching the one part in $$10^{18}$$1018 level. Comparisons between earthbound clocks at rest must account for the relativistic redshift of the clock frequencies, which is proportional to the corresponding gravity (gravitational plus centrifugal) potential difference. For contributions to international timescales, the relativistic redshift correction must be computed with respect to a conventional zero potential value in order to be consistent with the definition of Terrestrial Time. To benefit fully from the uncertainty of the optical clocks, the gravity potential must be determined with an a…
-
Frequency ratio measurements at 18-digit accuracy using an optical clock networkKyle Martha I. Tobias Samuel M. Sarah L. Jwo-Sy Jean-Da Beloy Bodine Bothwell Brewer Bromley Chen Deschêne, K. Beloy, M. I. Bodine et al. · 2021 · Nature · cited 362 times · Not summarized yet
The study uses an optical-clock network to measure frequency ratios at 18-digit accuracy, addressing high-precision clock comparison.
Go further
How are these papers found?
We compare the title and abstract of this paper with those of every paper summarized on this site, and with the papers Semantic Scholar recommends, those it cites and those citing it (for a much-cited paper, its most recent citations and, from OpenAlex, the most cited ones). Among the prior work and the follow-ups, the papers that use each other in depth, a method it uses and the much-cited follow-ups come a little higher. The levels (very close, close, related) come from the similarity of the texts, not from a judgment of quality; * marks a paper without an abstract, compared by its title. The sentence under a paper is written by an AI from the two abstracts: check it in the papers. A paper marked not relevant by three readers leaves the list.
Updated on 2 November 2026.
Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.