AI summary · arXiv: 2610.29980v1 · physics.atom-ph

International atomic clock comparison achieving $5\times 10^{-18}$ uncertainty

A. Tofful, M. Filzinger, T. Schmidt, A. Amy-Klein, E. Benkler, E. Cantin, C. Chardonnet, E. A. Curtis,

and 21 more authorsH. Denker, B. Dutta, J. -O. Gaudron, W. Huang, J. Kronjäger, A. Kuhl, R. Le Targat, B. Lipphardt, O. Lopez, S. Mukherjee, A. L. Parke, B. Pointard, P. -E. Pottie, P. J. Regan, M. Risaro, M. Schioppo, M. Steinel, J. Tunesi, X. Zhang, R. M. Godun, N. Huntemann

Original paper Submitted to arXiv on 21 Oct. 2026 10 pages, 7 figures License: NONEXCLUSIVE-DISTRIB 1.0 Also in: fr

The essentials

Two optical clocks compared internationally over a 2220 km fiber link agree within 4.8 × 10⁻¹⁸ fractional uncertainty and tighten constraints on Lorentz-invariance violations.

Based on the abstract only: check the details in the original paper.

Question

Can independently developed optical clocks in different countries demonstrate agreement below 5 × 10⁻¹⁸ fractional uncertainty? Can their comparison also constrain violations of Lorentz invariance?

Method

The researchers compared two single-ion optical clocks in the United Kingdom and Germany through a 2220 km optical fiber link, using more than one million seconds of measurement data. Both clocks use the electric octupole transition in ytterbium-171 ions. They also searched for statistically significant modulations to test Lorentz invariance.

Findings

  • Result The measured fractional frequency difference was 1.0 × 10⁻¹⁸ with an uncertainty of 4.8 × 10⁻¹⁸, demonstrating agreement between the independently developed clocks.
    See the passage in the paper
    Using more than $10^6$ seconds of measurement data, we determine a fractional frequency difference of $1.0(4.8)\times 10^{-18}$, demonstrating agreement of the independently developed systems.
  • Authors’ interpretation The authors identify this as, to their knowledge, the first international clock comparison with fractional uncertainty below 5 × 10⁻¹⁸.
    See the passage in the paper
    To our knowledge, this constitutes the first international clock comparison reaching a fractional uncertainty below $5\times 10^{-18}$, an important milestone towards an anticipated optical redefinition of the SI second.
  • Result No statistically significant modulations were found, and the uncertainty of constraints on the Robertson-Mansouri-Sexl parameter α improved by approximately a factor of five.
    See the passage in the paper
    In the absence of statistically significant modulations, we improve constraints on the Robertson-Mansouri-Sexl parameter $α$ by approximately a factor of five in the uncertainty, and provide limits on corresponding parameters within the Standard-Model Extension framework.

Limitations

  • The measurement uncertainty is dominated by the relativistic redshift correction between the sites, including time-varying gravitational potential differences.
    See the passage in the paper
    The measurement uncertainty is dominated by that of the relativistic redshift correction between the two sites, which includes time-varying gravity potential differences.

Why it matters

The authors present this international comparison as a milestone toward an anticipated optical redefinition of the SI second. The comparison also strengthens tests of Lorentz invariance through improved constraints in the Robertson-Mansouri-Sexl framework and limits within the Standard-Model Extension.

Written by AI from the paper. Passages are checked word for word against the text we analysed; the rest may contain errors.

AI-generated keywords: Optical atomic clocks; International frequency comparison; Ytterbium-171; Gravitational redshift; Lorentz invariance

Read further

  • Comprehensive Summary
  • Layman's Summary
  • Blog article
  • Original abstract
This paper presents a high-precision international comparison of two optical atomic clocks, testing whether independently developed systems in different countries agree at a fractional frequency uncertainty below 5 × 10⁻¹⁸. Such comparisons help establish the consistency of advanced timekeeping systems and support preparations for a possible optical redefinition of the SI second. The researchers also use the comparison to test Lorentz invariance, a fundamental principle of relativity. Only the paper’s title, author list, and abstract are available, so this summary cannot independently assess the experimental methods, uncertainty calculations, or supporting analyses. The experiment compares two single-ion optical clocks, one in the United Kingdom and the other in Germany, connected by a 2,220 km optical fiber link. Both clocks operate on the electric octupole (E3) transition in singly ionized ytterbium-171, connecting the ²S₁/₂ state with total angular momentum F = 0 to the ²F₇/₂ state with F = 3. Using the same atomic transition enables a direct test of agreement between the independently developed systems, while the fiber link allows their frequencies to be compared remotely. From more than one million seconds of measurement data, the researchers determine a fractional frequency difference of 1.0 × 10⁻¹⁸ with an uncertainty of 4.8 × 10⁻¹⁸, expressed in the abstract as 1.0(4.8) × 10⁻¹⁸. The result is consistent with zero within the reported uncertainty. According to the authors, this is the first international clock comparison to achieve a fractional uncertainty below 5 × 10⁻¹⁸. The abstract does not specify the uncertainty’s coverage convention or provide a detailed uncertainty budget. The dominant source of measurement uncertainty is the relativistic redshift correction between the two sites. Clocks at different gravitational potentials run at different rates, and this effect must be accounted for when comparing their frequencies. The correction incorporates time-varying gravitational-potential differences rather than treating the difference between the sites as fixed. This finding underscores the importance of precise gravitational-potential measurements in remote comparisons of highly accurate clocks. However, the abstract does not explain how these potential differences were determined or how their variations were modeled. The researchers also use the clocks’ large geographic separation to search for violations of Lorentz invariance. They report no statistically significant modulations in the comparison data. This null result reduces the uncertainty in constraints on the Robertson–Mansouri–Sexl parameter alpha by approximately a factor of five and establishes limits on corresponding parameters in the Standard-Model Extension framework. The abstract does not give numerical bounds or identify the specific Standard-Model Extension parameters constrained. Overall, the study demonstrates agreement between two internationally separated ytterbium-ion optical clocks at a reported fractional uncertainty of 4.8 × 10⁻¹⁸ while strengthening tests of fundamental physics. It marks an important step toward an optical redefinition of the SI second. The dominant uncertainty from the redshift correction also highlights a key challenge: further improvements require not only accurate clocks and reliable frequency transfer, but also sufficiently precise knowledge of gravitational-potential differences between sites.

Was this synthesis useful?

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

Ask questions about this paper to our AI assistant

Compare with the PDF

You can also chat with multiple papers at once here.

⚠The license of the paper does not allow us to build upon its content and the AI assistant only knows about the paper metadata rather than the full article.

Figures and plots

Ask about a figure by number or use its question button to request visual analysis. Up to two figures and four image panels per question. Values read from plots are approximate; check the original data.

AI assistant instructions?

Tools for this paper

Explain it differently 3 free rewrites left today
Save to a collection Group papers in collections to compare them, chat with them and export them. Create a free account Log in

Advanced tools Premium

For researchers who follow a field closely: citation alerts, journal-club slides, version comparison and Zotero export. Discover Premium

Zotero
Citation alerts
Weekly letter Presented in "Physics of matter and light this week" of 26 October 2026. Physics of matter and light this week: When flow, light and time resist expectations
Journal club Premium+ Slides to present it
Talk about it in public Premium+ Press kit: release, questions, hype check

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.