Automated CT Lung Cancer Screening Workflow using 3D Camera

AI-generated keywords: CT lung cancer screening automation patient positioning implicit generative model accuracy

AI-generated Key Points

The license of the paper does not allow us to build upon its content and the key points are generated using the paper metadata rather than the full article.

  • Recent advancements in CT planning allow for automation in patient positioning
  • Traditional process requires time-consuming scout scans for dose profiles and positioning
  • Researchers led by Brian Teixeira, Vivek Singh, Birgi Tamersoy, Andreas Prokein, and Ankur Kapoor developed a method eliminating the need for scout scans
  • Method estimates key parameters using 3D camera images trained on a dataset of over 60,000 CT scans
  • Unique strategy for updating predictions with real-time scan data
  • Validation tests showed impressive results with minimal errors in estimating isocenter, scan range, and Water Equivalent Diameter (WED)
  • Relative WED error well within acceptance criteria set by International Electrotechnical Commission
  • Represents significant advancement in CT lung cancer screening workflows by streamlining processes and reducing reliance on scout scans
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Brian Teixeira, Vivek Singh, Birgi Tamersoy, Andreas Prokein, Ankur Kapoor

Accepted at MICCAI 2023

Abstract: Despite recent developments in CT planning that enabled automation in patient positioning, time-consuming scout scans are still needed to compute dose profile and ensure the patient is properly positioned. In this paper, we present a novel method which eliminates the need for scout scans in CT lung cancer screening by estimating patient scan range, isocenter, and Water Equivalent Diameter (WED) from 3D camera images. We achieve this task by training an implicit generative model on over 60,000 CT scans and introduce a novel approach for updating the prediction using real-time scan data. We demonstrate the effectiveness of our method on a testing set of 110 pairs of depth data and CT scan, resulting in an average error of 5mm in estimating the isocenter, 13mm in determining the scan range, 10mm and 16mm in estimating the AP and lateral WED respectively. The relative WED error of our method is 4%, which is well within the International Electrotechnical Commission (IEC) acceptance criteria of 10%.

Submitted to arXiv on 27 Sep. 2023

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

The license of the paper does not allow us to build upon its content and the AI assistant only knows about the paper metadata rather than the full article.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 2309.15750v1

This paper's license doesn't allow us to build upon its content and the summarizing process is here made with the paper's metadata rather than the article.

In the field of CT lung cancer screening, recent advancements in CT planning have allowed for automation in patient positioning. However, despite these developments, the process still requires time-consuming scout scans to compute dose profiles and ensure proper patient positioning. In response to this challenge, a team of researchers led by Brian Teixeira, Vivek Singh, Birgi Tamersoy, Andreas Prokein, and Ankur Kapoor have developed a groundbreaking method that eliminates the need for scout scans in CT lung cancer screening. Their innovative approach involves estimating crucial parameters such as patient scan range, isocenter, and Water Equivalent Diameter (WED) using 3D camera images. This novel method is made possible through the training of an implicit generative model on a dataset comprising over 60,000 CT scans. Additionally,<nl>the researchers introduce a unique strategy for updating predictions using real-time scan data.</nl> To validate the effectiveness of their method,<nl>the team conducted tests on a set of 110 pairs of depth data and CT scans.</nl> The results were impressive,<nl>with an average error of only 5mm in estimating the isocenter,</nl><nl>13mm in determining the scan range,</nl><nl>and 10mm and 16mm errors in estimating the AP and lateral WED respectively.</nl> Notably,<nl>the relative WED error of their method was found to be just 4%, well within the International Electrotechnical Commission's acceptance criteria of 10%.</nl><np>This research represents a significant advancement in CT lung cancer screening workflows by streamlining processes and reducing reliance on time-consuming scout scans.</np>The potential impact of this innovative method extends beyond improving efficiency to enhancing accuracy and ultimately benefiting patients undergoing CT imaging for lung cancer screening.
Created on 23 Sep. 2024

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.