Sparsity Based Non-Contact Vital Signs Monitoring of Multiple People Via FMCW Radar

AI-generated keywords: Non-contact monitoring FMCW radar Vital Signs VSDR Healthcare

AI-generated Key Points

The license of the paper does not allow us to build upon its content and the key points are generated using the paper metadata rather than the full article.

  • Non-contact technology for monitoring vital signs of multiple people is important due to increasing prevalence of cardiopulmonary diseases, risk of transmitting infections, and heavy workload on medical staff
  • Frequency modulated continuous wave (FMCW) radars have potential in meeting these needs
  • Contemporary techniques for non-contact vital signs monitoring via FMCW radars face challenges in noisy environments with multiple objects
  • Yonathan Eder and Yonina C. Eldar developed an extended model of FMCW radar signals that can accurately localize humans and monitor their vital signs even in cluttered settings with multiple people using a single channel and a single-input-single-output setup
  • The authors utilize the sparse nature of modeled signals along with human-typical cardiopulmonary features to detect multiple people accurately and efficiently extract their Doppler samples through a joint sparse recovery approach
  • The authors introduce a method named Vital Signs based Dictionary Recovery (VSDR), which uses a dictionary-based approach to search for desired rates of respiration and heartbeat over high-resolution grids corresponding to normal cardiopulmonary activity given the extracted samples
  • Through examples combining real data from 30 monitored individuals with the proposed model, the authors demonstrate accurate human localization in clutter-rich scenarios that include both static and vibrating objects
  • The VSDR approach outperforms existing techniques based on several statistical metrics
  • FMCW radars with proposed algorithms provide an efficient way to monitor vital signs without contact while reducing risks associated with traditional methods such as physical contact or exposure to radiation
  • The proposed method could potentially revolutionize how medical professionals monitor patients' health by providing an accurate, non-invasive alternative that is easy to implement in various healthcare settings.
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Yonathan Eder, Yonina C. Eldar

Abstract: Non-contact technology for monitoring multiple people's vital signs, such as respiration and heartbeat, has been investigated in recent years due to the rising cardiopulmonary morbidity, the risk of transmitting diseases, and the heavy burden on the medical staff. Frequency modulated continuous wave (FMCW) radars have shown great promise in meeting these needs. However, contemporary techniques for non-contact vital signs monitoring (NCVSM) via FMCW radars, are based on simplistic models, and present difficulties coping with noisy environments containing multiple objects. In this work, we develop an extended model of FMCW radar signals in a noisy setting containing multiple people and clutter. By utilizing the sparse nature of the modeled signals in conjunction with human-typical cardiopulmonary features, we can accurately localize humans and reliably monitor their vital signs, using only a single channel and a single-input-single-output setup. To this end, we first show that spatial sparsity allows for both accurate detection of multiple people and computationally efficient extraction of their Doppler samples, using a joint sparse recovery approach. Given the extracted samples, we develop a method named Vital Signs based Dictionary Recovery (VSDR), which uses a dictionary-based approach to search for the desired rates of respiration and heartbeat over high-resolution grids corresponding to normal cardiopulmonary activity. The advantages of the proposed method are illustrated through examples that combine the proposed model with real data of $30$ monitored individuals. We demonstrate accurate human localization in a clutter-rich scenario that includes both static and vibrating objects, and show that our VSDR approach outperforms existing techniques, based on several statistical metrics. The findings support the widespread use of FMCW radars with the proposed algorithms in healthcare.

Submitted to arXiv on 10 May. 2022

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

The license of the paper does not allow us to build upon its content and the AI assistant only knows about the paper metadata rather than the full article.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 2205.05152v1

This paper's license doesn't allow us to build upon its content and the summarizing process is here made with the paper's metadata rather than the article.

Non-contact technology for monitoring vital signs of multiple people has gained importance in recent years due to the increasing prevalence of cardiopulmonary diseases, the risk of transmitting infections, and the heavy workload on medical staff. Frequency modulated continuous wave (FMCW) radars have shown great potential in meeting these needs. However, contemporary techniques for non-contact vital signs monitoring (NCVSM) via FMCW radars are based on simplistic models and face challenges in noisy environments containing multiple objects. To address this issue, Yonathan Eder and Yonina C. Eldar have developed an extended model of FMCW radar signals that can accurately localize humans and monitor their vital signs even in cluttered settings with multiple people using a single channel and a single-input-single-output setup. The authors utilize the sparse nature of modeled signals along with human-typical cardiopulmonary features to detect multiple people accurately and efficiently extract their Doppler samples through a joint sparse recovery approach. The authors then introduce a method named Vital Signs based Dictionary Recovery (VSDR), which uses a dictionary-based approach to search for desired rates of respiration and heartbeat over high-resolution grids corresponding to normal cardiopulmonary activity given the extracted samples. Through examples combining real data from 30 monitored individuals with the proposed model, the authors demonstrate accurate human localization in clutter-rich scenarios that include both static and vibrating objects. They also show that their VSDR approach outperforms existing techniques based on several statistical metrics. These findings support widespread use of FMCW radars with proposed algorithms in healthcare as they provide an efficient way to monitor vital signs without contact while reducing risks associated with traditional methods such as physical contact or exposure to radiation. The proposed method could potentially revolutionize how medical professionals monitor patients' health by providing an accurate, non-invasive alternative that is easy to implement in various healthcare settings.
Created on 13 Jun. 2023

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

The previous summary was created more than a year ago and can be re-run (if necessary) by clicking on the Run button below.

The license of this specific paper does not allow us to build upon its content and the summarizing tools will be run using the paper metadata rather than the full article. However, it still does a good job, and you can also try our tools on papers with more open licenses.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.