Molecular sieve vacuum swing adsorption purification and radon reduction system for gaseous dark matter and rare-event detectors

Auteurs : R. R. Marcelo Gregorio, N. J. C. Spooner, F. Dastgiri, A. C. Ezeribe, G. Lane, A. G. McLean, K. Miuchi, H. Ogawa

arXiv: 2312.07720v2 - DOI (physics.ins-det)
Soumis à arXiv le 12 Déc. 2023
Licence : CC BY 4.0
Résumé scientifique

In the field of directional dark matter experiments, SF6 has emerged as an ideal target gas. A critical challenge with this gas, and with other proposed gases, is the effective removal of contaminant gases. This includes radon which produce unwanted background events, but also common pollutants such as water, oxygen, and nitrogen, which can capture ionisation electrons, resulting in loss of detector gas gain over time. We present here a novel molecular sieve (MS) based gas recycling system for the simultaneous removal of both radon and common pollutants from SF6. The apparatus has the additional benefit of minimising gas required in experiments and utilises a Vacuum Swing Adsorption (VSA) technique for continuous, long-term operation. The gas system's capabilities were tested with a 100 L low-pressure SF6 Time Projection Chamber (TPC) detector. For the first time, we present a newly developed low-radioactive MS type 5A. This material was found to emanate radon at 98% less per radon captured compared to commercial counterparts, the lowest known MS emanation at the time of writing. Consequently, the radon activity in the TPC detector was reduced, with an upper limit of less than 7.2 mBq at a 95% confidence level (C.L.). Incorporation of MS types 3A and 4A to absorb common pollutants was found successfully to mitigate against gain deterioration while recycling the target gas.

Les articles autour de lui, par date et par proximité

Plus haut, c’est plus proche de cet article ; à gauche, c’est plus ancien. Les traits relient les articles proches entre eux : les groupes de traits sont des sous-thèmes. Sélectionnez un point pour voir pourquoi il est là. Retour au résumé de cet article

Comment lire cette carte ? Guide illustré

Les articles les plus proches Les travaux antérieurs sur lesquels il s’appuie Les articles qui le citent

Les articles autour de celui-ci

Classés selon la proximité de leur titre et de leur résumé avec ceux de cet article. Sélectionnez-en pour les lire ensemble.

Les articles les plus proches

  1. Très proche Cité par cet article
    Demonstration of radon removal from SF6 using molecular sieves
    A. Ezeribe, W. Lynch, R. R. Marcelo Gregorio et al. · 2017 · Journal of Instrumentation · cité 11 fois · Pas encore résumé
    Résumé scientifique

    The gas SF6 has become of interest as a negative ion drift gas for use in directional dark matter searches. However, as for other targets in such searches, it is important that radon contamination can be removed as this provides a source of unwanted background events. In this work we demonstrate for the first time filtration of radon from SF6 gas by using a molecular sieve. Four types of sieves from Sigma-Aldrich were investigated, namely 3Å, 4Å, 5Å and 13X. A manufactured radon source was used for the tests. This was attached to a closed loop system in which gas was flowed through the filters and a specially adapted Durridge RAD7 radon detector. In these measurements, it was found that only…

  2. Très proche Cité par cet article
    Test of low radioactive molecular sieves for radon filtration in SF6 gas-based rare-event physics experiments
    R. R. Marcelo Gregorio, N. Spooner, J. Berry et al. · 2020 · Journal of Instrumentation · cité 8 fois · Pas encore résumé
    Résumé scientifique

    Type 5 Å molecular sieves (MS) have been demonstrated to remove radon from SF6 gas. This is important for ultra-sensitive SF6 gas-based directional dark matter and related rare-event physics experiments, as radon can provide a source of unwanted background events. Unfortunately, commercially available sieves intrinsically emanate radon at levels not suitable for ultra-sensitive physics experiments. A method to produce a low radioactive MS has been developed in Nihon University (NU). In this work, we explore the feasibility of the NU-developed 5 Å type MS for use in such experiments. A comparison with a commercially available Sigma-Aldrich 5 Å type MS was made. The comparison was done by calc…

  3. Très proche Cité par cet article
    Construction and measurements of a vacuum-swing-adsorption radon-mitigation system
    R. Schnee, R. Bunker, G. Ghulam et al. · 2013 · arXiv: Instrumentation and Detectors · preprint, non relu par les pairs · cité 9 fois · Pas encore résumé
    Résumé scientifique

    Long-lived alpha and beta emitters in the 222Rn decay chain on (and near) detector surfaces may be the limiting background in many experiments attempting to detect dark matter or neutrinoless double beta decay, and in screening detectors. In order to reduce backgrounds from radon-daughter plate-out onto the wires of the Beta Cage during its assembly, an ultra-low-radon cleanroom is being commissioned at Syracuse University using a vacuum-swing-adsorption radon-mitigation system. The radon filter shows ∼20× reduction at its output, from 7.47±0.56 to 0.37±0.12 Bq/m3, and the cleanroom radon activity meets project requirements, with a lowest achieved value consistent with that of the filter, an…

  4. Proche Cité par cet article
    The novel properties of SF6 for directional dark matter experiments
    N. Phan, R. Lafler, R. Lauer et al. · 2016 · Journal of Instrumentation · cité 40 fois · Pas encore résumé
    Résumé scientifique

    SF6 is an inert and electronegative gas that has a long history of use in high voltage insulation and numerous other industrial applications. Although SF6 is used as a trace component to introduce stability in tracking chambers, its highly electronegative properties have limited its use in tracking detectors. In this work we present a series of measurements with SF6 as the primary gas in a low pressure Time Projection Chamber (TPC), with a thick GEM used as the avalanche and readout device. The first results of an 55Fe energy spectrum in SF6 are presented. Measurements of the mobility and longitudinal diffusion confirm the negative ion drift of SF6. However, the observed waveforms have a pec…

  5. Proche Cité par cet article Une méthode qu’il utilise
    Radon mitigation for the SuperCDMS SNOLAB dark matter experiment
    J. Street, R. Bunker, E. Miller et al. · 2017 · arXiv: Instrumentation and Detectors · preprint, non relu par les pairs · cité 10 fois · Pas encore résumé
    Résumé scientifique

    A potential background for the SuperCDMS SNOLAB dark matter experiment is from radon daughters that have plated out onto detector surfaces. To reach desired backgrounds, understanding plate-out rates during detector fabrication as well as mitigating radon in surrounding air is critical. A radon mitigated cleanroom planned at SNOLAB builds upon a system commissioned at the South Dakota School of Mines & Technology (SD Mines). The ultra-low radon cleanroom at SD Mines has air supplied by a vacuum-swing-adsorption radon mitigation system that has achieved >1000× reduction for a cleanroom activity consistent with zero and <0.067 Bq m−3 at 90% confidence. Our simulation of this system, validated …

  6. Proche Cité par cet article
    Gas gains over 104 and optimisation using 55Fe X-rays in low pressure SF6 with a novel Multi-Mesh ThGEM for directional dark matter searches
    A. G. McLean, N. Spooner, T. Crane et al. · 2023 · Journal of Instrumentation · cité 6 fois · Pas encore résumé
    Résumé scientifique

    The Negative Ion Drift (NID) gas SF6 has favourable properties for track reconstruction in directional Dark Matter (DM) searches utilising low pressure gaseous Time Projection Chambers (TPCs). However, the electronegative nature of the gas means that it is more difficult to achieve significant gas gains with regular Thick Gaseous Electron Multipliers (ThGEMs). Typically, the maximum attainable gas gain in SF6 and other Negative Ion (NI) gas mixtures, previously achieved with an 55Fe X-ray source or electron beam, is on the order of 103 [1,2,3,4]; whereas electron drift gases like CF4 and similar mixtures are readily capable of reaching gas gains on the order of 104 or greater [5,9,7,8,6]. In…

  7. Proche Cité par cet article
    Performance study of charcoal-based radon reduction systems for ultraclean rare event detectors
    M. Arthurs, D.-Q. Huang, C. Amarasinghe et al. · 2020 · Journal of Instrumentation · cité 4 fois · Pas encore résumé
    Résumé scientifique

    The continuous emanation of radon due to trace amounts of uranium and thorium in detector materials introduces radon to the active detection volume of low-background rare event search detectors. 222Rn produces a particularly problematic background in the physics region of interest by the “naked” beta decay of its 214Pb daughter nucleus. While charcoal-based adsorption traps are expected to be effective for radon reduction in auxiliary circulation loops that service the warm components of current ton-scale detectors at slow flow rates (0.5-2 SLPM), radon reduction in the entire circulation loop at high flow rates 𝒪(100s SLPM) is necessary to reach high sensitivity in future generation experim…

  8. Proche Cité par cet article Utilisé en profondeur par cet article Une méthode qu’il utilise
    Radon in the DRIFT-II directional dark matter TPC: emanation, detection and mitigation
    J. Battat, J. Brack, E. Daw et al. · 2014 · Journal of Instrumentation · cité 36 fois · Pas encore résumé
    Résumé scientifique

    Radon gas emanating from materials is of interest in environmental science and also a major concern in rare event non-accelerator particle physics experiments such as dark matter and double beta decay searches, where it is a major source of background. Notable for dark matter experiments is the production of radon progeny recoils (RPRs), the low energy (∼ 100 keV) recoils of radon daughter isotopes, which can mimic the signal expected from WIMP interactions. Presented here are results of measurements of radon emanation from detector materials in the 1 m3 DRIFT-II directional dark matter gas time projection chamber experiment. Construction and operation of a radon emanation facility for this …

Les travaux antérieurs sur lesquels il s’appuie

  1. Apparenté
    Demonstration of ThGEM-multiwire hybrid charge readout for directional dark matter searches
    A. Ezeribe, C. Eldridge, W. Lynch et al. · 2019 · Nuclear Instruments and Methods in Physics Research Section A : Accelerators, Spectrometers, Detectors and Associated Eq · cité 5 fois · Pas encore résumé
    Résumé scientifique

    Sensitivities of current directional dark matter search detectors using gas time projection chambers are now constrained by target mass. A ton-scale gas TPC detector will require large charge readout areas. We present a first demonstration of a novel ThGEM-Multiwire hybrid charge readout technology which combines the robust nature and high gas gain of Thick Gaseous Electron Multipliers with lower capacitive noise of a one-plane multiwire charge readout in SF$_6$ target gas. Measurements performed with this hybrid detector show an ion drift velocity of $139~\pm~12~\text{ms}^{-1}$ in a reduced drift field $\text{E/N}$ of $93~\text{Td}~(10^{-17}~\text{V cm}^{2})$ at a gas gain of $2470\pm160$ i…

  2. Apparenté
    Effective Design of a Vacuum Pressure Swing Adsorption Process To Recover Dilute Helium from a Natural Gas Source in a Methane-Rich Mixture with Nitrogen
    Parisa Eghbal Jahromi, S. Fatemi, A. Vatani · 2018 · Industrial & Engineering Chemistry Research · cité 14 fois · Pas encore résumé
    Résumé scientifique

    The conventional method of helium production is a cryogenic process, which is installed downstream of a liquefied natural gas (LNG) plant, where a helium extraction unit (HeXU) would be usually developed as the byproduct unit, due to the high cost of the process. In this study, pressure swing adsorption method accompanied by a relative vacuum condition for the bed regeneration (PVSA) was investigated as an alternative method for recovery of helium from natural gas source. The PVSA design was studied for a continuous product, utilizing zeolite 13X as the adsorbent, through a formerly validated model, for a dilute feed of 1.5 vol % He, mainly comprised of methane in 82.5 vol % accompanied by n…

  3. Apparenté
    A 50 l Cygno prototype overground characterization
    F. Amaro, R. Antonietti, E. Baracchini et al. · 2023 · The European Physical Journal C · cité 18 fois · Pas encore résumé
    Résumé scientifique

    The nature of dark matter is still unknown and an experimental program to look for dark matter particles in our Galaxy should extend its sensitivity to light particles in the GeV mass range and exploit the directional information of the DM particle motion (Vahsen et al. in CYGNUS: feasibility of a nuclear recoil observatory with directional sensitivity to dark matter and neutrinos, arXiv:2008.12587 , 2020). The Cygno project is studying a gaseous time projection chamber operated at atmospheric pressure with a Gas Electron Multiplier (Sauli in Nucl Instrum Meth A 386:531, https://doi.org/10.1016/S0168-9002(96)01172-2 , 1997) amplification and with an optical readout as a promising technology …

  4. Apparenté
    Effects of gas mixture quality on GEM detectors operation
    R. Guida, B. Mandelli, M. Corbetta · 2020 · Journal of Physics, Conference Series · cité 3 fois · Pas encore résumé
    Résumé scientifique

    Gas Electron Multiplier (GEM) detectors have been successfully operated in the LHCb experiment and they will be installed in the CMS and ALICE experiments during LHC Long Shutdown 2. As for others LHC gaseous detector systems, gas mixture is individually provided by dedicated Gas Systems. Several studies have been performed in laboratory to characterize GEM performance from the point of view of their use in LHC Gas Systems, where many variables can influence detectors operation. A Triple-GEM prototype was tested with the aim of probing the possible effects of specific changes that could occur in the Gas System, such as variations in gas mixture composition, input gas flow and presence of imp…

  5. Apparenté
    MIMAC: A micro-tpc matrix for directional detection of dark matter
    D. Santos, J. Billard, G. Bosson et al. · 2010 · Journal of Physics: Conference Series · cité 65 fois · Pas encore résumé
    Résumé scientifique

    Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. The first results on low energy nuclear recoils (1H and 19F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.

Comment ces articles sont-ils trouvés ?

Nous comparons le titre et le résumé de cet article avec ceux de tous les articles résumés sur ce site, et avec les articles que Semantic Scholar recommande, ceux qu’il cite et ceux qui le citent (pour un article très cité, ses citations les plus récentes et, depuis OpenAlex, les plus citées). Parmi les travaux antérieurs et les suites, les articles qui s’utilisent en profondeur, une méthode qu’il utilise et les suites très citées remontent un peu. Les niveaux (très proche, proche, apparenté) viennent de la similarité des textes, pas d’un jugement de qualité ; * signale un article sans résumé, comparé par son titre. La phrase sous un article est écrite par une IA à partir des deux résumés : vérifiez-la dans les articles. Un article jugé hors sujet par trois lecteurs quitte la liste.

Mis à jour le 2 novembre 2026.

Le guide illustré des articles autour d’un article