Hydraulic Parameter Estimation in District Heating Networks

AI-generated keywords: District heating hydraulic model grey-box parameterized valve numerical example

AI-generated Key Points

  • District heating networks are important sources of heat for many households and buildings.
  • Controlling the flow in these networks can be challenging, especially during peak demand periods.
  • Hydraulic models have been used to improve pumping efficiency and reduce sensitivity to hydraulic bottlenecks.
  • White-box models require full knowledge of the district heating network and its parameters, which can be time-consuming and may not accurately reflect the actual behavior of the system.
  • A new method has been proposed to obtain a grey-box hydraulic model for tree-shaped district heating systems, which estimates hydraulic parameters based on pressure measurements in only two locations and includes customer valves in the grey-box model structure.
  • The authors provide conditions for equations to have a unique solution and demonstrate the feasibility of their method through a numerical example with noisy measurements.
  • This approach allows for more efficient modeling of district heating networks while keeping accuracy with respect to measurements.
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Felix Agner, Pauline Kergus, Richard Pates, Anders Rantzer

License: CC BY 4.0

Abstract: Using hydraulic models in control design in district heating networks can increase pumping efficiency and reduce sensitivity to hydraulic bottlenecks. These models are usually white-box, as they are obtained based on full knowledge of the district heating network and its parameters. This type of model is time-consuming to obtain, and might differ from the actual behavior of the system. In this paper, a method is proposed to obtain a grey-box hydraulic model for tree-shaped district heating systems: hydraulic parameters are estimated based on pressure measurements in only two locations. While previous works only estimate parameters related to pressure losses in pipes, this work also includes customers valves in the grey-box model structure, an important inclusion for control-oriented applications. Finally, a numerical example illustrates the proposed method on a small district heating network, showing its ability to obtain an accurate model on the basis of noisy measurements.

Submitted to arXiv on 18 Nov. 2022

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 2211.10395v2

District heating networks are an important source of heat for many households and buildings. However, controlling the flow in these networks can be challenging, especially during peak demand periods. To address this issue, hydraulic models have been used to improve pumping efficiency and reduce sensitivity to hydraulic bottlenecks. These models are usually white-box, which means they require full knowledge of the district heating network and its parameters. However, obtaining such a model can be time-consuming and may not accurately reflect the actual behavior of the system. To overcome these limitations, a new method has been proposed to obtain a grey-box hydraulic model for tree-shaped district heating systems. This method estimates hydraulic parameters based on pressure measurements in only two locations and includes customer valves in the grey-box model structure, which is crucial for control-oriented applications. Previous works have only estimated parameters related to pressure losses in pipes; however, this work extends that by introducing a parameterized valve model in the grey-box identification process. The authors also provide conditions for equations to have a unique solution and demonstrate the feasibility of their method through a numerical example with noisy measurements. The contributions of this work include reducing non-linear hydraulic relations to linear equations with regards to parameters under consideration, providing conditions for unique solutions to these equations, and demonstrating the feasibility of their method through a numerical example. Overall, this paper presents an innovative approach that allows for more efficient modeling of district heating networks while keeping accuracy with respect to measurements. It has significant implications for improving flow control in existing networks as well as future generations of district heating systems.
Created on 07 Apr. 2023

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

The previous summary was created more than a year ago and can be re-run (if necessary) by clicking on the Run button below.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.