Thermostatic Hyperthermia with Non-invasive Temperature Monitoring through Speed of Sound Imaging

AI-generated keywords: Thermostatic hyperthermia Speed of Sound imaging HIFU Ultrasound transducer array Tumor therapy

AI-generated Key Points

  • Wang et al. propose a novel thermostatic hyperthermia model for tumor therapy incorporating non-invasive temperature monitoring through Speed of Sound (SOS) imaging.
  • High-intensity focused ultrasound (HIFU) is utilized for clinical tumor treatment, combined with diagnostic ultrasound image guidance.
  • HIFU heating is achieved using a ring ultrasound transducer array with 256 elements, allowing for precise and variable focus positioning at the tumor center.
  • Temperature detection is converted to SOS detection using the full-wave inversion (FWI) method based on inner structure information of thigh tissue obtained through B-mode ultrasound imaging and the relationship between temperature and SOS in different human tissues.
  • The proposed model achieves expected thermostatic hyperthermia on the tumor target with only a 0.2-degree maximum temperature fluctuation over 5 hours, demonstrating feasibility.
  • The system design allows for temperature measurement and thermostatic hyperthermia to share the same ultrasound transducer array, providing valuable guidance for future clinical applications.
  • Utilizing a ring ultrasound transducer array for HIFU heating and Speed of Sound Imaging during treatment showcases the model's effectiveness in maintaining constant temperatures throughout the process.
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Yuchan Wang, Yuening Wang, Yuan Jie, Paul Carson

arXiv: 2109.05709v1 - DOI (physics.med-ph)
License: CC BY 4.0

Abstract: Hyperthermia therapy (HT) is used to treat diseases through heating of high temperature usually in conjunction with some other medical therapeutics like chemotherapy and radiotherapy. In this study, we propose a promising thermostatic hyperthermia method that uses high-intensity focused ultrasound (HIFU) for clinical tumor treatment combined with diagnostic ultrasound image guidance and non-invasive temperature monitoring through the speed of sound (SOS) imaging. HIFU heating is realized by a ring ultrasound transducer array with 256 elements. The inner structure information of thigh tissue is obtained by B-mode ultrasound imaging. Since the relationship between the temperature and the SOS in the different human tissue is available, the temperature detection is converted to the SOS detection obtained by the full-wave inversion (FWI) method. Simulation results show that our model can achieve expected thermostatic hyperthermia on tumor target with 0.2 degree maximum temperature fluctuation for 5 hours. This study verifies the feasibility of the proposed thermostatic hyperthermia model. Furthermore, the temperature measurement can share the same ultrasound transducer array for HIFU heating and B-mode ultrasound imaging, which provides a guiding significance for clinical application.

Submitted to arXiv on 13 Sep. 2021

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 2109.05709v1

In this study, Wang et al. propose a novel thermostatic hyperthermia model for tumor therapy that incorporates non-invasive temperature monitoring through Speed of Sound (SOS) imaging. The method utilizes high-intensity focused ultrasound (HIFU) for clinical tumor treatment, combined with diagnostic ultrasound image guidance. The HIFU heating is achieved using a ring ultrasound transducer array with 256 elements, allowing for precise and variable focus positioning with a strong focusing effect at the tumor center. By obtaining inner structure information of thigh tissue through B-mode ultrasound imaging and leveraging the relationship between temperature and SOS in different human tissues, the researchers convert temperature detection to SOS detection using the full-wave inversion (FWI) method. Simulation results demonstrate that the proposed model can achieve expected thermostatic hyperthermia on the tumor target with only a 0.2-degree maximum temperature fluctuation over a period of 5 hours. This successful demonstration verifies the feasibility of the thermostatic hyperthermia model presented in this study. Additionally, by designing the system to allow for temperature measurement and thermostatic hyperthermia to share the same ultrasound transducer array, this research provides valuable guidance for future clinical applications. The experiment setup involved utilizing a ring ultrasound transducer array for HIFU heating and Speed of Sound Imaging to monitor temperature changes during treatment. The 3D temperature distribution at different time points illustrated how the model maintained constant temperatures throughout the process, showcasing its effectiveness in achieving long-term thermostatic hyperthermia. Overall, this study presents an innovative approach to tumor therapy that combines advanced imaging techniques with precise thermal control, offering promising implications for future medical equipment development and clinical practice.
Created on 27 Oct. 2024

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.