The effect of tissue physiological variability on transurethral ultrasound therapy of the prostate

AI-generated keywords: Therapeutic ultrasound Prostate cancer Computational simulations Tissue parameters Treatment efficacy

AI-generated Key Points

The license of the paper does not allow us to build upon its content and the key points are generated using the paper metadata rather than the full article.

  • Therapeutic ultrasound is a promising modality for minimally invasive treatment of prostate cancer
  • Study by Visa Suomi et al. used computational simulations to investigate impact of natural physiological variations in tissue parameters on efficacy of therapeutic ultrasound therapy in prostate
  • Patient CT data was used for simulations on clinical ultrasound therapy system
  • Key tissue parameters under scrutiny: attenuation, perfusion, specific heat capacity, thermal conductivity
  • Varying these parameters within biological ranges aimed to assess influence on peak temperature and thermal dose volume during therapeutic ultrasound treatment
  • Increased attenuation had most significant effect on peak temperature (6.9% rise)
  • Perfusion exhibited minimal impact with only +-0.2% variation in peak temperature
  • Specific heat capacity crucial factor affecting thermal dose volume (20.7% increase with reduced heat capacity)
  • Thermal conductivity had minor effect on thermal dose volume (up to 2.1% increase with decreased thermal conductivity)
  • Findings provide insights into how interpatient variability in tissue parameters can influence outcomes of therapeutic ultrasound treatment for prostate cancer
  • Understanding physiological variations can help tailor therapeutic ultrasound interventions for improved outcomes and personalized care strategies in prostate cancer management
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Visa Suomi, Bradley Treeby, Jiri Jaros, Jani Saunavaara, Aida Kiviniemi, Roberto Blanco

40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2018, pp. 5701-5704
arXiv: 1811.02874v1 - DOI (physics.med-ph)
Conference proceeding

Abstract: Therapeutic ultrasound is an investigational modality which could potentially be used for minimally invasive treatment of prostate cancer. Computational simulations were used to study the effect of natural physiological variations in tissue parameters on the efficacy of therapeutic ultrasound treatment in the prostate. The simulations were conducted on a clinical ultrasound therapy system using patient computed tomography (CT) data. The values of attenuation, perfusion, specific heat capacity and thermal conductivity were changed within their biological ranges to determine their effect on peak temperature and thermal dose volume. Increased attenuation was found to have the biggest effect on peak temperature with a 6.9% rise. The smallest effect was seen with perfusion with +-0.2% variation in peak temperature. Thermal dose was mostly affected by specific heat capacity which showed a 20.7% increase in volume with reduced heat capacity. Thermal conductivity had the smallest effect on thermal dose with up to 2.1% increase in the volume with reduced thermal conductivity. These results can be used to estimate the interpatient variation during the therapeutic ultrasound treatment of the prostate.

Submitted to arXiv on 07 Nov. 2018

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

The license of the paper does not allow us to build upon its content and the AI assistant only knows about the paper metadata rather than the full article.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 1811.02874v1

This paper's license doesn't allow us to build upon its content and the summarizing process is here made with the paper's metadata rather than the article.

Therapeutic ultrasound is a promising modality for the minimally invasive treatment of prostate cancer. In a study conducted by Visa Suomi, Bradley Treeby, Jiri Jaros, Jani Saunavaara, Aida Kiviniemi, and Roberto Blanco, computational simulations were utilized to investigate the impact of natural physiological variations in tissue parameters on the efficacy of therapeutic ultrasound therapy in the prostate. The researchers employed patient computed tomography (CT) data to conduct simulations on a clinical ultrasound therapy system. The key tissue parameters under scrutiny included attenuation, perfusion, specific heat capacity, and thermal conductivity. By varying these parameters within their biological ranges, the researchers aimed to assess their influence on peak temperature and thermal dose volume during therapeutic ultrasound treatment. The results revealed that increased attenuation had the most significant effect on peak temperature, leading to a 6.9% rise. In contrast, perfusion exhibited minimal impact with only a +-0.2% variation in peak temperature. Furthermore, specific heat capacity emerged as a crucial factor affecting thermal dose volume, showing a substantial 20.7% increase with reduced heat capacity. On the other hand, thermal conductivity had a minor effect on thermal dose volume, resulting in up to a 2.1% increase with decreased thermal conductivity. These findings provide valuable insights into how interpatient variability in tissue parameters can influence the outcomes of therapeutic ultrasound treatment for prostate cancer. By understanding these physiological variations and their effects on treatment efficacy, clinicians can better tailor therapeutic ultrasound interventions to individual patients for improved outcomes and personalized care strategies in prostate cancer management.
Created on 27 Oct. 2024

Assess the quality of the AI-generated content by voting

Score: 1

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.