Single-view 2D CNNs with Fully Automatic Non-nodule Categorization for False Positive Reduction in Pulmonary Nodule Detection

AI-generated keywords: Pulmonary Nodule Detection

AI-generated Key Points

The license of the paper does not allow us to build upon its content and the key points are generated using the paper metadata rather than the full article.

  • Study focuses on improving accuracy of pulmonary nodule detection by reducing false positives
  • Researchers propose a novel framework using ensemble of 2D CNNs with single views
  • Imbalance between nodules and non-nodules is a challenge in reducing false positives
  • Ensemble of 2D CNNs with single-view 2D patches overcomes problems of computational complexity and intra-class diversity
  • Non-nodules are categorized automatically using autoencoder and k-means clustering, eliminating manual categorization by radiologists
  • Training scheme extends learning capability and resolves difficulties in extracting features from non-nodules with large appearance variations
  • Proposed framework improves computational and memory efficiency compared to previous techniques relying on 3D CNNs
  • Outperforms existing methods based on 3D CNNs in terms of false positive reduction in pulmonary nodule detection
  • Utilizing ensemble of 2D CNNs with single views effectively addresses challenges associated with reducing false positives
  • Research presents a novel approach to improve accuracy of pulmonary nodule detection using ensemble of 2D CNNs and automatic categorization of non-nodules based on autoencoder and k-means clustering
  • Proposed framework shows promising results in reducing false positives and offers computational and memory efficiency advantages over existing methods.
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Hyunjun Eun, Daeyeong Kim, Chanho Jung, Changick Kim

Computer Methods and Programs in Biomedicine, vol. 165, Oct. 2018, pp. 215-224
12 pages, 16 figures

Abstract: Background and Objective: In pulmonary nodule detection, the first stage, candidate detection, aims to detect suspicious pulmonary nodules. However, detected candidates include many false positives and thus in the following stage, false positive reduction, such false positives are reliably reduced. Note that this task is challenging due to 1) the imbalance between the numbers of nodules and non-nodules and 2) the intra-class diversity of non-nodules. Although techniques using 3D convolutional neural networks (CNNs) have shown promising performance, they suffer from high computational complexity which hinders constructing deep networks. To efficiently address these problems, we propose a novel framework using the ensemble of 2D CNNs using single views, which outperforms existing 3D CNN-based methods. Methods: Our ensemble of 2D CNNs utilizes single-view 2D patches to improve both computational and memory efficiency compared to previous techniques exploiting 3D CNNs. We first categorize non-nodules on the basis of features encoded by an autoencoder. Then, all 2D CNNs are trained by using the same nodule samples, but with different types of non-nodules. By extending the learning capability, this training scheme resolves difficulties of extracting representative features from non-nodules with large appearance variations. Note that, instead of manual categorization requiring the heavy workload of radiologists, we propose to automatically categorize non-nodules based on the autoencoder and k-means clustering.

Submitted to arXiv on 09 Mar. 2020

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

The license of the paper does not allow us to build upon its content and the AI assistant only knows about the paper metadata rather than the full article.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 2003.04454v1

This paper's license doesn't allow us to build upon its content and the summarizing process is here made with the paper's metadata rather than the article.

The study focuses on improving the accuracy of pulmonary nodule detection by reducing false positives. The first stage of nodule detection involves identifying suspicious nodules, but this often results in a high number of false positives. To address this issue, the researchers propose a novel framework that utilizes an ensemble of 2D convolutional neural networks (CNNs) with single views. One challenge in reducing false positives is the imbalance between the numbers of nodules and non-nodules, as well as the intra-class diversity of non-nodules. While 3D CNNs have shown promising performance, they suffer from high computational complexity, making it difficult to construct deep networks. To overcome these problems, the researchers introduce an ensemble of 2D CNNs using single-view 2D patches. In their approach, non-nodules are categorized automatically using an autoencoder and k-means clustering, eliminating the need for manual categorization by radiologists. The researchers train all 2D CNNs using the same nodule samples but with different types of non-nodules. This training scheme extends the learning capability and resolves difficulties in extracting representative features from non-nodules with large appearance variations. The proposed framework improves both computational and memory efficiency compared to previous techniques that rely on 3D CNNs. It outperforms existing methods based on 3D CNNs in terms of false positive reduction in pulmonary nodule detection. The findings suggest that utilizing an ensemble of 2D CNNs with single views can effectively address the challenges associated with reducing false positives in pulmonary nodule detection. Overall, this research presents a novel approach to improve the accuracy of pulmonary nodule detection by utilizing an ensemble of 2D CNNs and automatic categorization of non-nodules based on an autoencoder and k-means clustering. The proposed framework shows promising results in reducing false positives and offers computational and memory efficiency advantages over existing methods.
Created on 11 Jul. 2023

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

The previous summary was created more than a year ago and can be re-run (if necessary) by clicking on the Run button below.

The license of this specific paper does not allow us to build upon its content and the summarizing tools will be run using the paper metadata rather than the full article. However, it still does a good job, and you can also try our tools on papers with more open licenses.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.