Innovative static spectropolarimeter concept for wide spectral ranges: tolerancing study

AI-generated keywords: Spectropolarimeter Space Applications Wide Spectral Range Stokes Vector Birefringence

AI-generated Key Points

The license of the paper does not allow us to build upon its content and the key points are generated using the paper metadata rather than the full article.

  • Development of an efficient and robust polarimeter for wide spectral ranges and space applications is crucial
  • Researchers in the UVMag consortium are exploring an innovative concept of a polarimeter that is simple, effective, and can operate over a wide spectral range
  • The idea is based on the use of polarization scramblers to create a spatial modulation of polarization
  • Variation in thickness of birefringent material generates intensity modulation of light related to entrance polarization state, enabling measurement of full Stokes vector over entire spectrum with single-shot measurement without any moving parts
  • Detailed tolerancing study on the optical bench using this spectropolarimeter after introducing its concept and optical design has been conducted
  • Proposed static spectropolarimeter concept offers several advantages over traditional methods including simplicity, efficiency, and robustness across wide spectral ranges suitable for space applications like Arago mission proposed to ESA.
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Martin Pertenais, Coralie Neiner, Laurent Parès, Pascal Petit

arXiv: 1509.00627v1 - DOI (astro-ph.IM)
6 pages, Proceeding SPIE Optics and Photonics, August 2015

Abstract: Developing an efficient and robust polarimeter for wide spectral ranges and space applications is a main issue in many projects. As part of the UVMag consortium created to develop UV facilities in space (e.g. the Arago mission proposed to ESA), we are studying an innovative concept of polarimeter that is robust, simple, and efficient on a wide spectral range. The idea, based on the article by Sparks et al. (2012), is to use polarization scramblers to create a spatial modulation of the polarization. Along the height of the wedges of the scramblers, the thickness of the birefringent material crossed by the light, and thus the retardance, vary continuously. This variation creates an intensity modulation of the light related to the entrance polarization state. Analyzing this modulation with a linear polarizer, and dispersing the light spectrally in the orthogonal spatial direction, enables the measurement of the full Stokes vector over the entire spectrum. This determination is performed with a single-shot measurement and without any moving parts in the system. After a quick introduction to the concept and optical design, this article presents the tolerancing study of the optical bench using this spectropolarimeter. The impact of different error sources, such as, birefringence uncertainty or decenter of the wedges, is investigated.

Submitted to arXiv on 02 Sep. 2015

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

The license of the paper does not allow us to build upon its content and the AI assistant only knows about the paper metadata rather than the full article.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 1509.00627v1

This paper's license doesn't allow us to build upon its content and the summarizing process is here made with the paper's metadata rather than the article.

The development of an efficient and robust polarimeter for wide spectral ranges and space applications is a crucial issue in many projects. As part of the UVMag consortium, which aims to develop UV facilities in space, researchers are exploring an innovative concept of a polarimeter that is simple, effective, and can operate over a wide spectral range. The idea is based on the use of polarization scramblers to create a spatial modulation of polarization. By varying the thickness of the birefringent material crossed by light along the height of the wedges of the scramblers, retardance also varies continuously. This variation generates an intensity modulation of light related to entrance polarization state. Analyzing this modulation with a linear polarizer and dispersing light spectrally in the orthogonal spatial direction enables measurement of full Stokes vector over entire spectrum with single-shot measurement without any moving parts. This article presents a detailed tolerancing study on the optical bench using this spectropolarimeter after introducing its concept and optical design. The study investigates different error sources such as birefringence uncertainty or decenter of wedges' impact on performance. The proposed static spectropolarimeter concept offers several advantages over traditional methods including simplicity, efficiency, and robustness across wide spectral ranges suitable for space applications like Arago mission proposed to ESA. The research team comprised Martin Pertenais, Coralie Neiner, Laurent Parès, and Pascal Petit who conducted this study published in Proceeding SPIE Optics and Photonics in August 2015 consisting six pages with DOI: 10.1117/12.2186294.
Created on 04 Apr. 2023

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

The previous summary was created more than a year ago and can be re-run (if necessary) by clicking on the Run button below.

The license of this specific paper does not allow us to build upon its content and the summarizing tools will be run using the paper metadata rather than the full article. However, it still does a good job, and you can also try our tools on papers with more open licenses.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.