TOT Measurement Implemented in FPGA TDC

AI-generated keywords: FPGA TDCs Time-over-Threshold Virtex-5 FPGA Resolution

AI-generated Key Points

The license of the paper does not allow us to build upon its content and the key points are generated using the paper metadata rather than the full article.

  • Time measurement is critical for particle identification in high energy physical experiments
  • Modern time measurement systems must meet high resolution specifications and maintain high integrity
  • Field Programmable Gate Array (FPGA) time-to-digital converters (TDCs) have become a mature and prominent method for time measurement due to their ability to provide excellent resolution and accuracy
  • To correct the time-walk effect caused by leading timing, it is necessary to include time-over-threshold (TOT) measurement in FPGA TDCs
  • Traditional TDCs can only recognize one type of signal edge - either leading or trailing - requiring two TDC channels to measure the interval accurately, which increases resource consumption and reduces integrity
  • A new method of TOT measurement implemented in a Xilinx Virtex-5 FPGA achieves accurate results using only one input channel while maintaining resource consumption, time resolution, and integrity guarantees
  • The TDC can achieve resolutions better than 15 ps for leading edge measurements and 37 ps for TOT measurements with a measuring dead time of about 2 clock cycles, making it suitable for applications with higher physical event rates.
  • This research demonstrates an innovative approach to improving TOT measurement in FPGA-based systems that could have significant implications for future particle identification experiments requiring highly accurate timing information.
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Huanhuan Fan, Ping Cao, Shubin Liu, Qi An

arXiv: 1501.06846v1 - DOI (physics.ins-det)
5 pages,9 figures

Abstract: Time measurement plays a crucial rule for the purpose of particle identification in high energy physical experiments. With the upgrading of physical goal and the developing of electronics, modern time measurement system meets the requirement of excellent resolution specification as well as high integrity. Due to Field Programmable Gate Array (FPGA), FPGA time-to-digital converter (TDC) becomes one of mature and prominent time measurement methods in recent years. For correcting time-walk effect caused by leading timing, time-over-threshold (TOT) measurement should be added in the FPGA TDC. TOT can be obtained by measuring the interval time of signal leading and trailing edge. Unfortunately, a traditional TDC can recognize only one kind of signal edge, the leading or the trailing. Generally, to measure the interval, two TDC channels can be used at the same time, one for leading, the other for trailing. However, this method will increase the amount of used FPGA resource and reduce the TDC's integrity unavoidably. This paper presents one method of TOT measurement implemented in a Xilinx Virtex-5 FPGA. In this method, TOT measure can be achieved in only one TDC input channel. The consumed resources and time resolution can both be guaranteed. Test shows that this TDC can achieve resolution better than 15 ps for leading edge measurement and 37 ps for TOT measurement. Furthermore, the TDC measuring dead time is about 2 clock cycles, which makes it be good for applications of higher physical event rate

Submitted to arXiv on 26 Jan. 2015

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

The license of the paper does not allow us to build upon its content and the AI assistant only knows about the paper metadata rather than the full article.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 1501.06846v1

This paper's license doesn't allow us to build upon its content and the summarizing process is here made with the paper's metadata rather than the article.

In high energy physical experiments, time measurement is a critical factor for particle identification. With the advancement of physical goals and electronics, modern time measurement systems must meet high resolution specifications and maintain high integrity. In recent years, Field Programmable Gate Array (FPGA) time-to-digital converters (TDCs) have become a mature and prominent method for time measurement due to their ability to provide excellent resolution and accuracy. To correct the time-walk effect caused by leading timing, it is necessary to include time-over-threshold (TOT) measurement in FPGA TDCs. TOT can be obtained by measuring the interval between signal leading and trailing edges. However, traditional TDCs can only recognize one type of signal edge - either leading or trailing. To measure the interval accurately, two TDC channels are typically used simultaneously - one for leading and one for trailing. Unfortunately, this approach increases the amount of FPGA resources required and reduces the TDC's integrity. This paper presents a new method of TOT measurement implemented in a Xilinx Virtex-5 FPGA that achieves accurate results using only one input channel. The method ensures both consumed resources and time resolution are guaranteed while maintaining high integrity. Test results show that this TDC can achieve resolutions better than 15 ps for leading edge measurements and 37 ps for TOT measurements with a measuring dead time of about 2 clock cycles. This makes it suitable for applications with higher physical event rates. Overall, this research demonstrates an innovative approach to improving TOT measurement in FPGA-based systems that could have significant implications for future particle identification experiments requiring highly accurate timing information.
Created on 08 May. 2023

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

The previous summary was created more than a year ago and can be re-run (if necessary) by clicking on the Run button below.

The license of this specific paper does not allow us to build upon its content and the summarizing tools will be run using the paper metadata rather than the full article. However, it still does a good job, and you can also try our tools on papers with more open licenses.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.