  • Authors address the challenge of implementing conventional grid-code specifications for dynamic ancillary services provision in converter-based generation systems
  • No customary methods have been developed yet for practical implementation of these specifications
  • Authors propose a systematic approach for practical implementation of piecewise linear time-domain curves to provide dynamic ancillary services
  • Approach ensures both grid code requirements and device level requirements are reliably satisfied
  • Key idea is to translate piecewise linear time domain curves into a desired rational parametric transfer function in the frequency domain
  • Obtained transfer function can be easily implemented using a PI based matching control in power loop of standard converter control architectures
  • Numerical grid code compliance tests conducted, comparing proposed approach with classical droop and virtual inertia schemes
  • Proposed method outperforms traditional schemes in terms of grid code compliance
  • Paper presents a systematic approach for implementing piecewise linear time domain curves in converter-based generation systems to provide dynamic ancillary services while ensuring compliance with grid codes and device level requirements
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Verena Häberle, Linbin Huang, Xiuqiang He, Eduardo Prieto-Araujo, Florian Dörfler

7 pages, 9 figures

Abstract: Conventional grid-code specifications for dynamic ancillary services provision such as fast frequency and voltage regulation are typically defined by means of piece-wise linear step-response capability curves in the time domain. However, although the specification of such time-domain curves is straightforward, their practical implementation in a converter-based generation system is not immediate, and no customary methods have been developed yet. In this paper, we thus propose a systematic approach for the practical implementation of piece-wise linear time-domain curves to provide dynamic ancillary services by converter-based generation systems, while ensuring grid-code and device-level requirements to be reliably satisfied. Namely, we translate the piece-wise linear time-domain curves for active and reactive power provision in response to a frequency and voltage step change into a desired rational parametric transfer function in the frequency domain, which defines a dynamic response behavior to be realized by the converter. The obtained transfer function can be easily implemented e.g. via a PI-based matching control in the power loop of standard converter control architectures. We demonstrate the performance of our method in numerical grid-code compliance tests, and reveal its superiority over classical droop and virtual inertia schemes which may not satisfy the grid codes due to their structural limitations.

Submitted to arXiv on 02 Oct. 2023

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

The license of the paper does not allow us to build upon its content and the AI assistant only knows about the paper metadata rather than the full article.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 2310.01552v3

This paper's license doesn't allow us to build upon its content and the summarizing process is here made with the paper's metadata rather than the article.

In this paper, the authors address the challenge of implementing conventional grid-code specifications for dynamic ancillary services provision in converter-based generation systems. These specifications typically involve defining piecewise linear step-response capability curves in the time domain for fast frequency and voltage regulation. While the specification of these curves is straightforward, their practical implementation in converter-based systems is not immediate and no customary methods have been developed yet. To overcome this challenge, the authors propose a systematic approach for the practical implementation of piecewise linear time-domain curves to provide dynamic ancillary services. Their approach ensures that both grid code requirements and device level requirements are reliably satisfied. The key idea behind their approach is to translate the piecewise linear time domain curves for active and reactive power provision into a desired rational parametric transfer function in the frequency domain. This transfer function defines the dynamic response behavior that needs to be realized by the converter. The obtained transfer function can be easily implemented using a PI based matching control in the power loop of standard converter control architectures. To demonstrate the effectiveness of their method, the authors conduct numerical grid code compliance tests. They compare their approach with classical droop and virtual inertia schemes which may not satisfy grid codes due to their structural limitations. The results show that their proposed method outperforms these traditional schemes in terms of grid code compliance. Overall, this paper presents a systematic approach for implementing piecewise linear time domain curves in converter based generation systems to provide dynamic ancillary services while ensuring compliance with grid codes and device level requirements. The proposed method offers a practical solution to an important problem in power system operation and control.
Created on 27 Nov. 2023

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

The previous summary was created more than a year ago and can be re-run (if necessary) by clicking on the Run button below.

The license of this specific paper does not allow us to build upon its content and the summarizing tools will be run using the paper metadata rather than the full article. However, it still does a good job, and you can also try our tools on papers with more open licenses.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.