Highly sensitive fire alarm system based on cellulose paper with low temperature response and wireless signal conversion

AI-generated keywords: Fire Detection Early Warning Graphene Oxide Titanium Carbide Smart Fire Alarm

AI-generated Key Points

  • Highly sensitive smart sensors for early fire detection with remote warning capabilities are urgently needed
  • Flame-retardant cellulose paper loaded with graphene oxide (GO) and two-dimensional titanium carbide (Ti3C2, MXene) used to design a novel fire alarm
  • GO acts as an electrical insulator at room temperature and becomes electrically conductive at high temperatures
  • MXene enhances fire detection speed and warning at low temperatures below 300°C
  • Flame-retardant fire alarm paper exhibits highly-sensitive response to abnormal temperature during pre-combustion process
  • Rapid response time of 2 seconds at a relatively low temperature of 250°C allows for safe rescue and evacuation before fire develops further
  • Novel method based on light intensity used to evaluate response time of the fire-warning system
  • Wireless signal conversion and communication device integrated into the fire-warning system for the first time
  • Device converts received signal into wireless signals and displays fire warning message on LCD screen within a radius of 2 km from incident location when high temperature or other signs of potential fires are detected
  • Smart fire alarm paper shows promise for use as smart wallpaper for interior house decoration and other applications requiring early fire detection and warning
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Xiaolu Li, Jose Sanchez del Rio Saez, Xiang Ao, Abdulmalik Yusuf, De-Yi Wang

arXiv: 2201.05442v1 - DOI (physics.app-ph)
License: CC BY 4.0

Abstract: Highly sensitive smart sensors for early fire detection with remote warning capabilities are urgently required to improve the fire safety of combustible materials in diverse applications. The highly-sensitive fire alarm can detect fire situation within a short time quickly when a fire disaster is about to occur, which is conducive to achieve fire tuned. Herein, a novel fire alarm is designed by using flame-retardant cellulose paper loaded with graphene oxide (GO) and two-dimensional titanium carbide (Ti3C2, MXene). Owing to the excellent temperature dependent electrical resistance switching effect of GO, it acts as an electrical insulator at room temperature and becomes electrically conductive at high temperature. During a fire incident, the partial oxygen-containing groups on GO will undergo complete removal, which results in the conductivity transformation.Besides the use of GO feature, this work also introduces conductive MXene to enhance fire detection speed and warning at low temperature, especially below 300 {\deg}C. The designed flame-retardant fire alarm is sensitive enough to detect fire incident, showing a response time of 2 s at 250 {\deg}C, which is calculated by a novel and quantifiable technique. More importantly, the designed fire alarm sensor is coupled to a wireless communication interface to conveniently transmit fire signal remotely. Therefore, when an abnormal temperature is detected, the signal is wirelessly transmitted to a liquid crystal display (LCD) screen when displays a message such as "FIRE DANGER". The designed smart fire alarm paper is promising for use as a smart wallpaper for interior house decoration and other applications requiring early fire detection and warning.

Submitted to arXiv on 28 Dec. 2021

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 2201.05442v1

Highly sensitive smart sensors for early fire detection with remote warning capabilities are urgently needed to improve the fire safety of combustible materials in various applications. In this study, a novel fire alarm is designed using flame-retardant cellulose paper loaded with graphene oxide (GO) and two-dimensional titanium carbide (Ti3C2, MXene). The GO acts as an electrical insulator at room temperature and becomes electrically conductive at high temperatures due to its excellent temperature dependent electrical resistance switching effect. During a fire incident, the oxygen-containing groups on GO are completely removed, resulting in a conductivity transformation. Additionally, the MXene enhances fire detection speed and warning at low temperatures below 300°C. The flame-retardant fire alarm paper exhibits a highly-sensitive response to abnormal temperature during the pre-combustion process, with a rapid response time of 2 seconds at a relatively low temperature of 250°C. This quick response time allows for more time to ensure safe rescue and evacuation of people before the fire develops further. A novel method based on light intensity is demonstrated to evaluate the response time of the fire-warning system, providing a more quantifiable and precise measurement. Furthermore, a wireless signal conversion and communication device is integrated into the fire-warning system for the first time. This device successfully converts the received signal from the fire warning system into wireless signals and displays a fire warning message on an LCD screen within a radius of 2 km from the incident location when high temperature or other signs of potential fires are detected. The designed smart fire alarm paper shows promise for use as smart wallpaper for interior house decoration and other applications requiring early fire detection and warning. By utilizing highly sensitive sensors and remote warning capabilities, this technology can significantly enhance existing safety measures against uncontrolled fires by providing timely warnings that can help prevent irreparable casualties or property loss caused by such incidents.
Created on 18 Dec. 2023

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

The previous summary was created more than a year ago and can be re-run (if necessary) by clicking on the Run button below.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.