Pulmonary drug delivery and retention: a computational study to identify plausible parameters based on a coupled airway-mucus flow model

AI-generated keywords: Pulmonary drug delivery systems

AI-generated Key Points

The license of the paper does not allow us to build upon its content and the key points are generated using the paper metadata rather than the full article.

  • Pulmonary drug delivery systems are crucial for systemic drug delivery via inhalation of drug-laden aerosols
  • Challenges such as mucociliary advection can transport drug molecules away from their intended site of action in the lungs
  • A mathematical model has been developed to analyze drug deposition and retention in the lungs, aiming to optimize conditions for effective systemic drug delivery
  • Aerosols with sizes ranging from 1-5 µm are most effective in delivering drugs to deep lung regions
  • Doubling the breathing time period can lead to a twofold increase in drug deposition in the deep lung, suggesting breath control as a strategy for enhancing drug delivery efficiency
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Aranyak Chakravarty, Mahesh V. Panchagnula, Alladi Mohan, Neelesh A. Patankar

arXiv: 2012.00676v4 - DOI (q-bio.TO)
24 pages

Abstract: Pulmonary drug delivery systems rely on inhalation of drug-laden aerosols produced from aerosol generators such as inhalers, nebulizers etc. On deposition, the drug molecules diffuse in the mucus layer and are also subjected to mucociliary advection which transports the drugs away from the initial deposition site. The availability of the drug at a particular region of the lung is, thus, determined by a balance between these two phenomena. A mathematical analysis of drug deposition and retention in the lungs is developed through a coupled mathematical model of aerosol transport in air as well as drug molecule transport in the mucus layer. The mathematical model is solved computationally to identify suitable conditions for the transport of drug-laden aerosols to the deep lungs. This study identifies the conditions conducive for delivering drugs to the deep lungs which is crucial for achieving systemic drug delivery. The effect of different parameters on drug retention is also characterized for various regions of the lungs, which is important in determining the availability of the inhaled drugs at a target location. Our analysis confirms that drug delivery efficacy remains highest for aerosols in the size range of 1-5 $\mu$m. Moreover, it is observed that amount of drugs deposited in the deep lung increases by a factor of 2 when the breathing time period is doubled, with respect to normal breathing, suggesting breath control as a means to increase the efficacy of drug delivery to the deep lung. A higher efficacy also reduces the drug load required to be inhaled to produce the same health effects and hence, can help in minimizing the side effects of a drug.

Submitted to arXiv on 21 Nov. 2020

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

The license of the paper does not allow us to build upon its content and the AI assistant only knows about the paper metadata rather than the full article.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 2012.00676v4

This paper's license doesn't allow us to build upon its content and the summarizing process is here made with the paper's metadata rather than the article.

, , , , Pulmonary drug delivery systems are essential for achieving systemic drug delivery through the inhalation of drug-laden aerosols. These aerosols, generated from devices like inhalers and nebulizers, deposit drug molecules in the mucus layer of the lungs. However, once deposited, these drug molecules face challenges such as mucociliary advection, which can transport them away from their intended site of action. To address this issue, a coupled mathematical model of aerosol transport in air and drug molecule transport in the mucus layer has been developed to analyze drug deposition and retention in the lungs. This computational study aims to identify optimal conditions for transporting drug-laden aerosols to the deep lung regions where systemic drug delivery is most effective. By examining various parameters affecting drug retention in different lung regions, the study provides insights into enhancing the availability of inhaled drugs at specific target locations within the lungs. The analysis confirms that aerosols with sizes ranging from 1-5 µm exhibit the highest efficacy in delivering drugs to the deep lungs. Additionally, it was observed that doubling the breathing time period led to a twofold increase in the amount of drugs deposited in the deep lung, suggesting that breath control could be utilized as a strategy to enhance drug delivery efficacy. Through increasing drug delivery efficacy, lower doses of drugs may be required to achieve therapeutic effects, potentially minimizing side effects associated with higher dosages. Overall, this study offers valuable insights into optimizing pulmonary drug delivery systems for more efficient and targeted administration of medications within the respiratory system.
Created on 24 Mar. 2024

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

The previous summary was created more than a year ago and can be re-run (if necessary) by clicking on the Run button below.

The license of this specific paper does not allow us to build upon its content and the summarizing tools will be run using the paper metadata rather than the full article. However, it still does a good job, and you can also try our tools on papers with more open licenses.

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.