Optimal DG allocation and sizing in power system networks using swarm-based algorithms

AI-generated keywords: Distributed Generation

AI-generated Key Points

  • Distributed Generation (DG) units are crucial for enhancing grid architecture and efficiency
  • Careful planning and execution of DG unit installation is necessary to avoid voltage instability and excessive costs
  • Researchers developed particle swarm optimization (PSO) and whale optimization algorithm (WOA) to optimize DG unit placement and sizing
  • Adetunji et al. used PSO and WOA along with loss sensitivity factors (LSF) to identify ideal locations for DG units in IEEE 14-bus and 30-bus test systems
  • Both PSO and WOA algorithms showed promising results, with WOA excelling in real power loss reduction while PSO was more efficient in reducing total DG unit size
  • MATLAB environment was used for simulations on an Intel(R) Core(TM) i7-3520M @ 2.90 GHz processor
  • Parameters were selected to focus on minimizing power loss and improving voltage profiles within the network
  • Two-stage procedure involved identifying potential buses using LSF technique followed by meta-heuristic optimization for optimal DG unit placement and sizing
  • Study highlights the effectiveness of PSO and WOA algorithms in optimizing allocation and sizing of DG units in transmission networks
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Kayode Adetunji, Ivan Hofsajer, Ling Cheng

License: CC BY 4.0

Abstract: Distributed generation (DG) units are power generating plants that are very important to the architecture of present power system networks. The benefit of the addition of these DG units is to increase the power supply to a network. However, the installation of these DG units can cause an adverse effect if not properly allocated and/or sized. Therefore, there is a need to optimally allocate and size them to avoid cases such as voltage instability and expensive investment costs. In this paper, two swarm-based meta-heuristic algorithms, particle swarm optimization (PSO) and whale optimization algorithm (WOA) were developed to solve optimal placement and sizing of DG units in the quest for transmission network planning. A supportive technique, loss sensitivity factors (LSF) was used to identify potential buses for optimal location of DG units. The feasibility of the algorithms was confirmed on two IEEE bus test systems (14- and 30-bus). Comparison results showed that both algorithms produce good solutions and they outperform each other in different metrics. The WOA real power loss reduction considering techno-economic factors in the IEEE 14-bus and 30-bus test system are 6.14 MW and 10.77 MW, compared to the PSOs' 6.47 MW and 11.73 MW respectively. The PSO has a more reduced total DG unit size in both bus systems with 133.45 MW and 82.44 MW compared to WOAs' 152.21 MW and 82.44 MW respectively. The paper unveils the strengths and weaknesses of the PSO and the WOA in the application of optimal sizing of DG units in transmission networks.

Submitted to arXiv on 19 Feb. 2020

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 2002.08089v1

In the realm of power system networks, Distributed Generation (DG) units play a crucial role in enhancing the overall architecture and efficiency of the grid. These units are instrumental in bolstering power supply to networks, but their installation must be carefully planned and executed to avoid potential drawbacks such as voltage instability and excessive investment costs. To address this challenge, researchers have developed two swarm-based meta-heuristic algorithms, namely particle swarm optimization (PSO) and whale optimization algorithm (WOA), aimed at optimizing the placement and sizing of DG units for transmission network planning. In their study, Adetunji et al. utilized these algorithms alongside a supportive technique known as loss sensitivity factors (LSF) to pinpoint ideal locations for DG unit deployment within the IEEE 14-bus and 30-bus test systems. The comparison results revealed that both PSO and WOA algorithms yielded promising solutions, with each showcasing strengths in different performance metrics. For instance, WOA demonstrated superior real power loss reduction considering techno-economic factors in both test systems compared to PSO. On the other hand, PSO exhibited a more efficient total reduction in DG unit size across the bus systems. The research was conducted using MATLAB environment with simulations executed on an Intel(R) Core(TM) i7-3520M @ 2.90 GHz processor. The parameters employed in the algorithms were meticulously selected to focus on minimizing power loss and improving voltage profiles within the network. A two-stage procedure was adopted for optimal DG unit placement and sizing, beginning with identifying potential buses using LSF technique followed by meta-heuristic optimization. Overall, this study sheds light on the efficacy of PSO and WOA algorithms in optimizing the allocation and sizing of DG units within transmission networks. By leveraging these advanced computational techniques, researchers aim to mitigate operational challenges while maximizing energy efficiency in modern power systems.
Created on 13 Jun. 2024

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

The previous summary was created more than a year ago and can be re-run (if necessary) by clicking on the Run button below.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.